Controls And Indicators; Power Led; Feed Button - Intermec EasyCoder E4 Installation And Operation Manual

Bar code label printer
Hide thumbs Also See for EasyCoder E4:
Table of Contents

Advertisement

Chapter 2
Installation
Controls and
Indicators

Power LED

Feed Button

10
The EasyCoder E4 has one control (the Feed button) and one
indicator (the Power LED.) The Power LED is tri-colored and
indicates the status of the printer.
LED shows
No light:
Green:
• Steady
• Flashing
• Single Flash
Amber:
• Steady
• Momentarily
Red:
• Steady
• Single fl ash
Power LED
Feed button
Press Feed to dispense a blank label, if no label design has been
downloaded to the printer.
Press Feed to print a label after a label design has been downloaded
to the printer and the Feed button has been set up to work as a Print
button (see Chapter 3, "Operation/Printing a Label.)" You can also
use Feed to print a test label (see Chapter 3, "Operation/Printing
Test Labels.)"
Meaning
Power off
Power on
Busy (executing or receiving data)
Bar code successfully read
Bar code wand active (lasts max. 10 sec:s)
During power on
Bar code wand inactive
Error condition, for example...
- Printhead lifted
- Out of media
- Out of ribbon
- Media jam in cutter
Bar code reading failed
Intermec EasyCoder E4 – Installation & Operation Ed. 2

Advertisement

Table of Contents
loading

Table of Contents