How To Self-Check And Initialize The Dvr With Dvd Player - Symphonic CSHP80G Service Manual

Dvr(hdd) with dvd player
Hide thumbs Also See for CSHP80G:
Table of Contents

Advertisement

HOW TO SELF-CHECK AND INITIALIZE THE DVR with DVD Player

1. Turn on the DVR with DVD Player recorder.
2. To put the DVR with DVD Player recorder into the HDD mode, press [DVR] on the remote control unit.
3. To put the DVR with DVD Player recorder into the self-check mode, after pressing [ANGLE] button, press the
[3], [6], and [9] buttons on the remote control in that order within three seconds.
Fig. a appears on the screen and all LEDs light.
Table 1: Description of Fig. a
INDICATION
HDD CONNECT STATUS (*1)
HDD POWER ON HOURS (*2)
BE Ver. (*3)
Sub Micon Ver. (*4)
4. Upon the self-check completion, Fig. b appears on the screen.
Table 2: Indication of HDD self-check (*5)
INDICATION
OK
NOT FOUND
CABLE ERROR
" ******* " differs depending on the models.
Self-Analysys and Report
*1
HDD CONNECT STATUS :
*2
HDD POWER ON HOURS :
*3
BE Ver. :
*4
Sub Micon Ver. :
Fig. a: Self-Check Mode Screen
Connecting Condition of HDD
Value of HDD power on hours obtained from S.M.A.R.T. command. (If not obtainable,
value of HDD power on hours is "0".)
Value in parentheses is the factory setting value. (If no setting, the value is "0".)
B/E version
Sub micro controller version
" ******* " differs depending on the models.
Self-Analysys and Report
*5
HDD CONNECT STATUS :
HDD POWER ON HOURS :
BE Ver. :
Sub Micon Ver. :
*6
FACTORY DEFAULT :
*7
POWER OFF :
Fig. b: Screen of Finishing Self-Check Mode
Connection of HDD is normal.
HDD drive cannot be found.
FFC cable between the ATA CBA and the HDD drive is not connected correctly.
G6*******Q1U
NFQ2B**D1
DESCRIPTION
OK
100(40)
G6*******Q1U
NFQ2B**D1
ENTER
POWER
DESCRIPTION
1-7-1
E41A1INT

Advertisement