Locating Fireplace - Empire Comfort Systems DVL36BP30 Series Installation Instructions Manual

Direct-vent gas fireplace heater
Table of Contents

Advertisement

CORNER
INSTALLATION
ANGLED CORNER
INSTALLATION
NOTE: Island and Room Divider installation is possible as long as
the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
NOTE: When installing this fireplace against an exterior wall, insulate
to applicable insulation codes.
Page 18

LOCATING FIREPLACE

ISLAND
INSTALLATION
When you install your Direct Vent Fireplace in Room divider or Flat
on wall corner positions, a minimum of 10 inches clearance must
be maintained from the perpendicular wall and the front opening
of the fireplace.
Figure 7
CABINET
INSTALLATION
FLUSH WALL
INSTALLATION
ROOM DIVIDER
INSTALLATION
41978-1-1220