Chapter 6 Configuring Your Printer Using the Menus

6.8 Menu Mode Description

Group Menu
* Page Setup
Label Width
Print Speed
Print Darkness
Print Method
Ribbon Torque
Continu. MediaLen
Vertical Position
Horizont Shift
* System Setup
Media Sensor
Sensor Monitor
Sensor Level
Top Form
Buzzer Select
Metric/Inch
Print Res. DPI
(Print Res. DPmm)
AutoCal Mode
MaxMedia Length
(continued)
Menu Item
Default Value
8.53in
216.7mm
04 IPS
10
TT
3
10.00in
254.0mm
0.00in
0.00mm
10.00in
254.0mm
See Thru
¾
1.5V/1.7V
Yes
Exec/Err
Inch
300
10.00in
250.0mm
Range of Values
3.00 - 8.64in
76.2 - 219.5mm
02 - 04 IPS
00 - 30*
DT / Direct Thermal
TT / Thermal Transfer
1 - 5
0.25 - 40.00in
6.4 - 1016.0mm
- 1.00 - 1.00in
-25.4 - 25.4mm
- 1.00 - 1.00in
-25.4 - 25.4mm
See Thru
Notch
Reflect White
Reflect Blue
None
x.xV adc
0.0V - 3.3V
Yes
No
Exec/Err
All
Error
Key
None
Inch
mm
300DPI(12 DPmm)
150DPI(6 DPmm)
1.00 - 50.00in
25.4mm - 1270.0mm
-
-
48
Description
Set print label width.
¾
*When language is DDP-N3, the
maximum value is 20.
Set printing method.
Set ribbon winding torque
Set print label length
Adjust print start position.
Adjust left-to-right position in dots.
Select label sensor.
See Thru: Transparent GAP sensor.
Notch: Transparent HOLE sensor.
Reflect White: Reflective White base
sensor.
Reflect Blue: Reflective Blue base
sensor.
None: No use of sensor (continuous
paper)
Monitor media sensor sensing level.
When None, See Thru (GAP) sensor
sensing level is monitored.
Set sensor threshold.
Select Top-Of-Form (TOF) sensing.
Printer will feed to top-of-form before
first print after power on.
Select condition for buzzer.
Exec/Err: Sounds when setting and
execution are completed or error
occurs.
All: Sounds in all situations.
Error: Sounds only in error.
Key: Sounds in key operation.
None: No sound.
Set basic unit of measurement to
millimeters or inches.
Set print resolution.
Values in parentheses are in metric
system.
Perform sensor calibration.
Set GAP length.