Exterior Loading; Merchandisers Shipped With End Installed; Shipping Braces; Leveling - Hussmann MWG Installation And Operation Manual

Medium temperature merchandisers
Hide thumbs Also See for MWG:
Table of Contents

Advertisement

I
1-2
NSTALLATION

EXTERIOR LOADING

Do NOT walk on top of merchandisers or
damage to the merchandisers and serious
personal injury could occur. T
STRUCTURALLY DESIGNED TO SUPPORT EXCESSIVE
such as the weight of a
EXTERNAL LOADING
person. Do not place heavy objects on the case.
MERCHANDISERS SHIPPED
WITH END INSTALLED
If the case was shipped with the end installed,
two long bolts were used to hold the shipping
brace to the end. If the shipping bolts are
reinserted after removing the brace, they will
extend into the product area. T
SURE TO REPLACE THESE BOLTS WITH THE SHORTER
. NSF requires any bolt or screw
BOLTS PROVIDED
in the product area be capped or cut off if it has
more than three exposed threads.
Be careful not to damage the factory
installed end while moving the case.
Make sure that tools are positioned past
the end and beneath the merchandiser's
support bar.

SHIPPING BRACES

Move the merchandiser as close
as possible to its permanent
location and then remove all
packaging. Check for damage
before discarding packaging.
Remove all separately packed
accessories such as kits and
shelves.
P/N 0378414G
HEY ARE NOT
,
HEREFORE
BE
NOTE:
WARNING
!
Do NOT remove shipping braces until
the merchandisers are positioned
for installation.

LEVELING

Merchandisers must be installed level to ensure
proper operation of the refrigeration system and
to ensure proper drainage of defrost water. When
leveling merchandisers, use a carpenter's level as
shown. Leveling shims are provided with each
merchandiser for use if needed. The shims are big
enough so that you can level adjoining merchan-
disers at the same time using one shim.
NOTES:
• B
EGIN LINEUP LEVELING FROM THE HIGHEST POINT
.
OF THE STORE FLOOR
• If shimming two corners, check to see if a shim is
needed in the center of the merchandiser. If a gap
exists between the support rail of the merchandiser
and the floor, a shim should be placed in the center.
Serial Plate
Levels
Front of
Merchandiser