Download Print this page

Shelving, Temperature Control, Condensing Unit - Hussmann EVM Installation And Service Instructions Manual

Medium temperature merchandiser

Advertisement

SHELVING -
The EVM models come equipped with
four shelves. They are adjustable on one inch
increments. When loading the shelves with
product, they should be loaded so that the prod-
uct does not extend over the front edge of the
shelf. Product loaded over the edge will inter-
fere with air circulation in the cabinet. It is also
desirable to leave a small space between the rear
interior wall and the product
to allow air to enter the cabinet interior through
the perforations in the rear wall.
The shelves are rated for 130 pounds
each load capacity. When installing the shelves,
first install the shelf support bracket at the de-
sired height. Place the rear of the bracket in the
desire slot. Raise the front of the bracket to-
wards the rear of the cabinet. Once the ends are
in the slot, rotate the bracket forward locking it
in place. Place the shelf on the bracket. Load
the product. The shelves are not to be slanted.
They must remain in a horizontal position.
TEMPERATURE CONTROL –
Interior cabinet temperatures are con-
trolled through the use of a bulb and capillary
type temperature control. The control is located
in the electrical box. The sensing element is
mounted on the left hand end of the evaporator
coil. The dial face of the control is marked with
readings that range from –10 to +50ºF.
The control is factory preset at 25º to 27º
to maintain 35-40º interior cabinet tempera-
tures. The differential is set at 8-10º, which is
the difference between cycle on and off tempera-
tures.
Turning the dial counter-clockwise will
achieve lower temperatures and turning it
clock wise will achieve higher temperatures.
directly correspond to the actual cabinet tem-
perature due to the sensing element location and
ambient conditions.
diate temperature changes. Allow some time be-
tween settings for the system to balance out.
on the shelves
the cabinet. Remove the front access panel and
electrical box cover. Loosen and remove screws
securing the control in place. Remove the prod-
uct from the base shelf of cabinet. Lift up and
remove base shelves. Remove the screws holding
the fan motor plenum and rotate plenum for-
ward. Remove the screws holding the coil cover
in place and remove it. Locate and remove plas-
tic cover in lower left hand of perforated back
panel. The control sensing element is located
behind this plastic cover. Reaching through,
slide the element from its holder. Remove the
control. Feed the element for the new control
through the cabinet in reverse order. Reseal all
penetrations around the new element.
finish reassembling in reverse order. Secure the
control body in the electrical box. Replace all
covers. Turn power supply back on and allow
cabinet to reach proper operating temperatures
before reloading.
PAGE 6
The indicated dial temperature will not
Turning the dial will not result in imme-
To replace the control, turn off power to
Place the element back in its holder and

Advertisement