Yamaha DPX-1000 Service Manual page 39

Digital cinema projector
Hide thumbs Also See for DPX-1000:
Table of Contents

Advertisement

2 Error message indicating detection of de-
vice error by the self-diagnosis command
Required tools
• PC
DOS/V machine, OS: Windows 95/98/Me, with a serial
port (RS232C)
• Self-diagnostic program
Service Utility (SU) for DPX-1000 Version: 1.00C
• RS232C connection cable
Cross cable "D-sub 9pin female"
For the specific set-up procedure, refer to "HOW TO USE
THE SERVICE UTILITY".
1) Device error
Example of error message: when OK
OK
Example of error message: when NG
NG $$$$$$
In the above example, $$$$$$ represents the displayed
error device name given in the tables under the item "1:
Device error".
2) Others
• Test pattern display
This function is used to specify the faulty point when a trouble
occurred.
When this command is input, a test pattern is provided
through AMDP2 of the CSP2 P.C.B.
For the self-diagnosis command other than the above com-
mands, refer to "HOW TO USE THE SERVICE UTILITY".
Device error diagnosis command /デバイス異常診断コマンド
Command name
Name of P.C.B. being diagnosed
コマンド名
診断対象基板名
diag all
All of below P.C.B.s /下記の全基板
diag adp
diag csp
diag cn
diag cw
diag op
diag fmt
diag adc̲hlck
Command name
Test pattern name
コマンド名
テストパターン名
diag testp 20
100% white & color bar Ramp
2 自己診断コマンドによるデバイス異常検出
 必要なツール
・ PC 
DOS/V 機、OS : Window95/98/Me、シリアルポート付き
(RS232C)
・ 自己診断プログラム
Service Utility (SU) for DPX-1000  Version : 1.00C
・ RS232C 接続ケーブル
クロスケーブル  D-sub 9pin メス
セットアップについての詳細は
ティーの使用方法 をご覧ください。
1) デバイス異常
エラーメッセージ例 OK の場合
  
OK
エラーメッセージ例 NG の場合
NG  $$$$$$
上記 $$$$$$ の部分には 1: デバイス異常 項目にある
表のエラー表示デバイス名が表示されます。  
ADP
CSP
CN
CW
OP
FMT
ADP
2) その他
・テストパターン表示
トラブル時の不良個所を特定するために用います。 
このコマンド入力によりCSP2基板のAMDP2よりテストパ
ターンが出力されます。
上記コマンド以外の自己診断コマンドについては、
サービスユーティリティーの使用方法 をご覧ください。
DPX-1000
サービスユーティリ
39

Advertisement

Table of Contents
loading

Table of Contents