4. PERFORMANCE DATA

[a] KML-200MAE
APPROXIMATE
ICE PRODUCTION
PER 24 HR.
lbs./day (kg./day)
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
gal./day (m
3
/day)
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
PSIG
SUCTION PRESSURE
2
PSIG (kg/cm
G)
TOTAL HEAT OF REJECTION
Note: Pressure data is recorded first 5 minutes in freezing cycle.
The data without *marks should be used for reference.
* We reserve the right to make changes in specifications and design without prior notice.
AMBIENT
TEMP. ( °F/°C )
70/21
*250 (113)
80/27
241 (109)
90/32
230 (104)
100/38
218 ( 99)
70/21
80/27
90/32
100/38
70/21
*81 ( 0.31 )
80/27
75 ( 0.28 )
90/32
73 ( 0.28 )
100/38
71 ( 0.27 )
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
5980 Btu/h [AT 90°F (32°C) / WT 70°F (21°C)]
26
WATER TEMP. ( °F/°C )
50/10
70/21
240 (109)
226 (103)
*214 ( 97)
203 ( 92)
*770
776
774
784
776
*790
787
797
73 ( 0.28 )
62 ( 0.24 )
*54 ( 0.20 )
51 ( 0.19 )
*20
21
21
23
21
*24
24
26
*2.5
2
2
2
2
*2
3
2
*260
268
266
278
268
*286
268
288
*25
26
26
28
26
*30
31
33
90/32
220 (100)
210 ( 95)
199 ( 90)
187 ( 85)
801
818
821
850
63 ( 0.24 )
54 ( 0.20 )
44 ( 0.17 )
*36 ( 0.14 )
28
32
32
*40
2
2
2
*2
276
284
293
*300
36
42
42
*53