Performance Data; Kmd-901Mah (Air-Cooled) - Hoshizaki KMD-901MWH Service Manual

Modular crescent cuber
Hide thumbs Also See for KMD-901MWH:
Table of Contents

Advertisement

C. Performance Data

1. KMD-901MAH (air-cooled)

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
890
70/21
80/27
870
90/32
864
100/38
843
70/21
80/27
90/32
100/38
70/21
372
80/27
325
90/32
310
100/38
240
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
231
80/27
246
90/32
251
100/38
258
70/21
36
80/27
38
90/32
39
100/38
41
30
WATER TEMP. (ºF/ºC)
50/10
70/21
404
864
395
830
392
801
382
784
1810
1848
1839
1898
1848
1940
1845
1945
1.41
310
1.23
228
1.17
160
0.91
157
16
17
16
18
17
19
17
19
3.3
3.0
3.0
2.4
3.0
2.0
2.5
2.0
16.2
251
17.3
276
17.6
298
18.1
306
2.5
39
2.7
43
2.7
46
2.9
48
16,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
90/32
392
803
364
376
754
342
363
730
331
356
665
302
1876
1913
1961
1980
1.17
280
1.06
0.86
230
0.87
0.61
148
0.56
0.60
136
0.52
18
20
21
23
2.8
2.5
2.0
2.0
17.6
281
19.8
19.4
309
21.7
21.0
330
23.2
21.5
360
25.3
2.7
45
3.2
3.0
51
3.6
3.2
53
3.7
3.4
60
4.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmd-901mahKmd-901mrh

Table of Contents