INSTALLATION

A. To Remove Existing Toilet
Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.
Remove old gasket from the floor and
closet flange with a putty knife.
Remove old T-bolts and discard them.
NOTICE:
if a new toilet is not installed
immediately, temporarily stuff a rag in
the closet flange.
B. Roughing-In
DANGER: Risk of electric shock.
before servicing.
NOTE:
This product is designed to work with either wall or
floor mounted electrical and water supplies. Both types are
shown in the rough-in art.
WARNING: Risk of electric shock.
circuits protected by Ground-Fault Circuit-Interrupters
(GFCI s) or Earth-Leakage Circuit-Breakers (ELCB s).
'
When the electrical supply is mounted on the wall, a GFCI or
ELCB protected and water proof receptacle is required.
Follow the dimensional information exactly when installing a
hardwire electrical supply.
C. Install the T-Bolts
Install two new 8mm (5/16") diameter
T-bolts into the floor flange.
Do not use white cement or high lime
content cements to install this toilet.
The expansion of cement due to a rise
in temperature may make the toilet
crack or cause damage. Kohler is not
responsible for any damage caused by
installation with the use of cement.
1061926-T01-A
A.
Closet Flange
Fig.#2
2
B.
Disconnect power
Connect only to
'
T-Bolts
T
Fig.#3
3
(GFCI)
(ELCB)
C.
Floor Flange
T
(ELCB)
(GFCI)
T
8mm
(5/16")
T