Marantz SR7013 Service Manual page 111

Hide thumbs Also See for SR7013:
Table of Contents

Advertisement

3-4. Error Code H1-06 failure detection procedure
Checking device.
[IC401 :
ADV8003]
Check the power supply voltage.
Check item(3-4.1.).
Check the power supply volt-
age. :
Does the power supply voltage of the GUI [IC401]
indicate the appropriate voltage (1.8V, 3.3V)?
The test points are as follows.
1.8V
3.3V
IC401
L4007
CN401 4pin
YES
GUI [IC401] is faulty.
Replace with a new device.
Recheck from
check item (3.1.)
If it does not work, replace the PCB.
NO
Check item(3-4.2.).
Check the power supply volt-
age. :
Check the power supply components
[IC111,
Q1105] on the substrate and peripheral pattern.
If there is no problem, remove the GUI [IC401]
from the substrate and measure the voltage at
the test point of
check item
(3-4.1.).
Is the voltage correct (1.8V or 3.3V)?
YES
NO
The power supply circuit is faulty.
Replace the PCB.
Checking the reset waveform.
Check item(3-4.3.).
Checking the reset :
Check the CPU.
Is the waveform of the TP near the GUI [IC401] correct (like the one
shown in the diagram) when the power is turned on?
IC401
TP113
YES
NO
Check the reset circuit between CPU [IC151] and GUI [IC401].
If there is no problem, the GUI [IC401] is faulty.
Replace with a new device.
Recheck from
check item (3.1.)
If it does not work, replace the PCB.
111
10ms
10ms
Example of the waveform to be checked
Voltage scale : 1.0V/div
Time scale : 20ms/div
Go to next page.
10ms

Advertisement