12 Troubleshooting
Error code
Detailed error
code
8F
00
C0
00
U3
00
81
00
C4
00
80
00
U5
00
U4
00
AC
00
EC
00
HC
00
CJ
02
H1
00
89
02
A1
01
AH
00
Installer reference guide
82
Description
Abnormal increase outlet
water temperature (DHW).
Flow sensor/switch malfunction.
Please contact your dealer.
Under floor heating screed
dryout function not completed
correctly.
Leaving water temperature
sensor problem.
Please contact your dealer.
Heat exchanger temperature
sensor problem.
Please contact your dealer.
Returning water temperature
sensor problem.
Please contact your dealer.
User interface
communication problem.
Indoor/outdoor unit
communication problem.
Booster heater overheated.
Please contact your dealer.
Abnormal increase tank
temperature.
Tank temperature sensor
problem.
Please contact your dealer.
Room temperature sensor
problem.
Please contact your dealer.
External temperature
sensor problem.
Please contact your dealer.
Heat exchanger frozen.
EEPROM reading error.
Tank disinfection function not
completed correctly.
Error code
Detailed error
code
89
03
AJ
03
UA
17
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
▪ When the Domestic hot water > Type > Reheat or
Reheat + sched. is selected, it is recommended to
program the start-up of the disinfection function at least
4  hours later than the last expected large hot water
tapping. This start-up can be set by installer settings
(disinfection function).
▪ When the Domestic hot water > Type > Scheduled only
is selected, it is recommended to program a Storage
eco 3  hours before the scheduled start-up of the
disinfection function to preheat the tank.
NOTICE
When the minimum water flow (in relation to the applicable
operation mode) is lower than described in the table below,
the unit will stop operation and the user interface will
display error 7H.
Minimum required flow during heat pump operation
04 models
Heating
Cooling
08 models
Heating
Cooling
11 models
Heating
Cooling
16 models
Heating
Cooling
Minimum required flow during defrost operation
04+08 models
11+16 models
Minimum required flow during backup heater operation
All models
INFORMATION
Error AJ-03 is reset automatically from the moment there is
a normal tank heat-up.
ERLQ004~008CA + EHVH/X04+08S18+26CB
Description
Heat exchanger frozen.
Too long DHW heat-up time
required.
Tank type problem
6 l/min
6 l/min
6 l/min
10 l/min
10 l/min
15 l/min
10 l/min
15 l/min
12 l/min
15 l/min
12 l/min
Daikin Altherma – Low temperature split