Denon AVRX6500HBKE3 Service Manual page 114

Integrated network av receiver/amplifier

Advertisement

3-10. Error Code H1-10 failure detection procedure
Checking device.
[U301 :
ADSP21487]
Checking the reset waveform. (DSP3)
Check item(3-10.1.).
Checking the reset :
Check the CPU.
Is the waveform of the TP near the DSP [U301] correct (like the one
shown in the diagram) when the power is turned on?
U301
RESET
YES
NO
Check the reset circuit between CPU [U6201] and DSP [U301].
If there is no problem, the DSP [U301] is faulty.
Replace with a new device.
Recheck from
check item (3.1.)
If it does not work, replace the PCB.
Check the SPI communication line. (DSP3)
Check item(3-10.2.).
Check the CPU.
Is the "SPI" waveform of the TP near the DSP [U301] correct (like
the one shown in the diagram) when the power is turned on?
Examples of confirmation waveform
Voltage scale : 1.0V/div
Time scale : 20ms/div
YES
DSP [U301] is faulty.
Replace with a new device.
Recheck from
If it does not work, replace the PCB.
114
Check the SPI communication line :
CS
U301
NO
Check item(3-10.3.).
Check the SPI communication line :
Check DSP [U301], CPU [U6201] patterns as well as soldering.
If there is no problem, go to the next step.
check item (3.1.)
*The diagram shows an example.
(Signal patterns vary depending on the tim-
ing.)
Points for checking waveforms
- Crest value (3.3V normally)
- Signal change
Voltage scale : 2.0V/div
Time scale : 2us/div