Initializing one-touch tuning

Servo parameters to be initialized
Initialize one-touch tuning to restore the setting value of the following servo parameters to the factory setting.
In addition, [Pr. PA08.0 Gain adjustment mode selection] will be automatically changed to "1" (Auto tuning mode 1).
Servo parameter
Symbol
PA08
ATU
PA09
RSP
PA24
AOP4
PB01
FILT
PB02
VRFT
PB03
PST
PB06
GD2
PB07
PG1
PB08
PG2
PB09
VG2
PB10
VIC
PB12
OVA
PB16
NHQ2
PB17
NHF
PB18
LPF
PB23
VFBF
PB47
NHQ3
PB49
NHQ4
PB51
NHQ5
PE41.0
*1 Available only on the MR-J5-_A_. The MR-J5_-_G_ and MR-J5_-_B_ do not have this servo parameter.
Name
Auto tuning mode
Auto tuning response
Function selection A-4
Adaptive tuning mode (adaptive filter II)
Vibration suppression control tuning mode
(advanced vibration suppression control II)
Position command speed adjustment time
*1
constant (position smoothing)
Load to motor inertia ratio/load to motor
mass ratio
Model control gain
Position control gain
Speed control gain
Speed integral compensation
Overshoot amount compensation
Notch shape selection 2
Shaft resonance suppression filter
Low-pass filter setting
Low-pass filter selection
Notch shape selection 3
Notch shape selection 4
Notch shape selection 5
Robust filter selection
Remark
[Pr. PA08.0] is set to "1" (Auto tuning mode 1).
[Pr. PB16.0 Machine resonance suppression filter 2 selection]
is initialized to "0".
[Pr. PB47.0 Machine resonance suppression filter 3 selection]
is initialized to "0".
[Pr. PB49.0 Machine resonance suppression filter 4 selection]
is initialized to "0".
[Pr. PB51.0 Machine resonance suppression filter 5 selection]
is initialized to "0".
3 ADJUSTMENT METHOD
3.2 One-touch tuning
3
39