Repair
Remove Air Motor
1. Follow Pressure Relief Procedure, page 9.
2. Disconnect displacement pump from air motor. See
steps 2 and 3 under Remove Displacement
Pump, page 23.
3. Disconnect sensor cable, air line, and ground wire
from air motor.
4. Remove mounting screws (5) and washers (4)
holding air motor (2 or 3) to mounting bracket.
F
. 3
IG
5. Refer to your XL Air Motor manual to service or
repair the air motor.
6. Reconnect ground wire and sensor cable. Follow
steps in reverse order to reinstall air motor.
Drum Feed RAM Pump
Assembly (Feed Module)
NOTE: See Drum Feed RAM Pump assembly (227) in
parts breakdown beginning on page 45.
24
See your Supply Systems manual for service and repair
instructions and parts.
Flush Pump
1. Follow Pressure Relief Procedure, page 9.
2. Disconnect pump inlet line (154) and air lines (57,
60) from flush pump.
3. Disconnect fluid outlet line.
2 or 3
4. Remove four screws (153) that attach flush
pump (8) to bracket (152) and remove flush pump.
Bracket
8
4
5
57
154
5. Refer to your Merkur Pump Assembly manual to
service or repair flush pump 257463.
6. Follow steps in reverse order to reinstall flush
pump.
152
153
60
3A8047B