Table 2-8. System Messages (continued)
Message
Processor n internal error Faulty microprocessor; faulty system
Processor bus parity error
Processor in socket 1 not
installed!
Remote access controller
error
Remote access controller
is not present
SCSI cable not present on
connector A or B of the
primary backplane
Shutdown failure
Spare bank enabled
System backplane error
System halted! Must power
down
The amount of system
memory has changed
Time-of-day clock stopped
Time-of-day not set -
please run SETUP program
Causes
board.
No microprocessor installed in
primary microprocessor socket.
Embedded remote access memory
may be temporarily corrupted.
SCSI cable is loose, improperly
connected, or faulty.
Shutdown test failure.
Memory spare bank enabled
Faulty or improperly installed SCSI
backplane board.
Wrong password entered too many
times.
Memory has been added or removed
or a memory module may be faulty.
Faulty battery.
Incorrect Time or Date settings; faulty
system battery.
Corrective Actions
See "Troubleshooting the
Microprocessors" in "Troubleshooting
Your System."
Install a microprocessor in the primary
microprocessor socket. See "Processors"
in "Installing System Options."
This message is not applicable to this
system.
This message is not applicable to this
system.
See "Troubleshooting System Memory"
in "Troubleshooting Your System."
This message is not applicable to this
system.
This message is not applicable to this
system.
Information only.
If memory has been added or removed,
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" in "Troubleshooting Your
System."
See "Troubleshooting the System
Battery" in "Troubleshooting Your
System."
Check the Time and Date settings. See
"Using the System Setup Program" in
the User's Guide. If the problem persists,
replace the system battery. See
"Replacing the System Battery" in
"Installing System Options."
Indicators, Codes, and Messages
27