Table 2-8. System Messages (continued)
Message
Memory parity failure at
start address to end
address
Memory parity error at
address
No boot device available
No boot sector on hard-
disk
No PXE-capable device
available
No timer tick interrupt
Not a boot diskette
PCI BIOS failed to install Loose cables to expansion card(s);
Causes
Faulty or improperly installed memory
modules.
Faulty or missing CD/diskette drive
subsystem, hard drive, or hard-drive
subsystem.
No operating system on hard drive.
<F12> pressed during POST and no
PXE devices are detected.
Faulty system board.
No operating system on diskette.
faulty or improperly installed
expansion card.
Corrective Actions
See "Troubleshooting System Memory"
in "Troubleshooting Your System."
Use a bootable diskette, CD, or hard
drive. If the problem persists, see
"Troubleshooting a Diskette Drive,"
"Troubleshooting a CD Drive,"
"Troubleshooting SCSI Hard Drives,"
and "Troubleshooting SATA Hard
Drives" in "Troubleshooting Your
System."
Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
in the User's Guide.
Check the configuration settings in the
System Setup program for the NICs. See
"Using the System Setup Program" in
the User's Guide. If the problem persists,
see "Troubleshooting a NIC" in
"Troubleshooting Your System."
See "Getting Help."
Use a bootable diskette.
Ensure that all appropriate cables are
securely connected to the expansion
cards. If the problem persists, see
"Troubleshooting Expansion Cards" in
"Troubleshooting Your System."