Download Print this page

Prior To Installation - Jøtul FS 166 -I 570 Installation And Operating Instructions Manual

Advertisement

4.0 Prior to installation

4.1 Foundations
You need to make sure the foundation is suitable for a stove. See
"2.0 Technical data" for specified weight.
Remember: If a steel chimney resting on the burn chamber is
being used, the weight of the steel chimney should be taken
into account.
NB: It is extremely important that the product be stable; the
surface it is installed on must be completely inflexible.
It is recommended that flooring that is not attached to the
foundation – «floating floors» – be removed beneath the product.
4.2 Floor covering
Jøtul FS 166 - I 570 has an airtight bottom plate and no
extra floor covering is required beneath the product.
Any floor covering of inflammable material, such as linoleum,
carpets, etc. must be removed from under the product.
4.3 Floor plate
A plate made of steel or some other suitable non-inflammable
metal (optional extra) is placed in front of the hearth.
The floor plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
4.4 Air supply
There must be a flow of air between the burn chamber and the
surround. This is to ensure that there is not too great a build-up
of heat inside the surround.
NB: It is extremely important that air openings not be covered.
See fig. 1 for distances.
4.5 Steel chimney
If a top-mounted steel chimney is used, an uninsulated pipe is
fitted from the burn chamber to approximately 10 mm through
the top stones. Make sure that the gasket is properly seated
between the flue pipe and the smoke outlet. Then fit the steel
chimney in accordance with the chimney supplier's installation
instructions.
4.6 Ceiling
Make sure the room where the Jøtul FS 166 - I 570 is to be placed
has a ceiling height of at least 2300 mm.
4.8 Chimney and flue pipe
The stove must be connected to a chimney and flue pipe
approved for solid fuel fireplaces with flue gas temperatures
as specified in «2.0 Technical data» in the insert manual.
The cross-section of the chimney must be at least that of the
flue pipe. To calculate the correct chimney cross section, see
«2.0 Technical data» in the insert manual.
Several solid fuel products can be connected to the same
chimney system if the chimney cross-section is adequate.
Contact your local building authorities regarding restrictions
and installation requirements.
Connection to the chimney must be performed in accordance
with the installation instructions of the chimney supplier.
Make sure that the flue pipe rises all the way up to the chimney.
Please note that it is extremely important for connections to
have a degree of flexibility.
For recommended chimney draught, see «2.0 Technical data» in
the insert manual.
4.8 Preparation
The basic product is supplied in two packages:
1. the burn chamber,
2. and soap stones with mounting sections.
NB: Check that there is no visible damage to the product when
you unpack it, and make sure that the control handles move
freely.
The burn chamber is heavy, – make sure it does not topple over
while you are installing it!
Ensure you have help when positioning and installing it.
The product is supplied together with 3 manuals:
1. General user and maintenance manual
2. Jøtul FS 166 - I 570 (surround)
3. Jøtul I 570 (burn chamber)
The surround consists of the following elements
(Fig. 2):
Part
Description
2
Bottom plate
3
Leg
4 pcs
4
Insert support plate
5
Side stone
6
Corner stone
7
Front stone
8
Distance piece
9
Corner stone over insert
10
Top stone, front
11
Top stone, left
12
Top stone, right
13
Top grid 1 pcs
14
Support bracket
15
Rear plate, upper 1 pcs
16
Rear plate, middle 1 pcs
17
Rear plate, lower 1 pcs
18
Bracket 1 6 pcs
19
Bracket 3 10 pcs
20
Bracket 6
21
Bracket 5 4 pcs
22
Bracket 2 6 pcs
23
Bracket 4
24
Screw countersink unb, M6x16
25
Heat shield, top
26
Adjustable leg
27
Heat shield for flue pipe
28
Screw Hexagon, M10x35
29
Screw hexagon cap flange, M6x10
30
Nut hexagon cap flange, M6
Prior to installation, decide on the following:
1. Where the smoke outlet should be.
2. Ash collection system if being used.
Refer to manuals for parts installation instructions.
ENGLISH
1 pcs
1 pcs
12 pcs
10 pcs
4 pcs
4 pcs
2 pcs
1 pcs
1 pcs
1 pcs
1 pcs
4 pcs
4 pcs
8 pcs
1 pcs
4 pcs
1 pcs
4 pcs
2 pcs
2 pcs
Total
41

Advertisement

loading