Empire Comfort Systems MILLIVOLT DVCD FP3-4 Series Installation Instructions Manual page 77

Direct-vent zero clearance gas fireplace heater
Table of Contents

Advertisement

INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING
PROBLEM OBSERVED
Gas odor during setup
Gas odor before first ignition
Fireplace is
"on"
but no flame and pilot is
not trying to light
Pilot continues to spark when pilot is lit.
Pilot will not ignite, or will not stay lit
Burner takes too long to fully light
Burner does not light but pilot remains on
Burner lights but does not stay lit while
pilot remains on
38712-4-0920
POSSIBLE CAUSE
Gas Leak
Gas Leak
Gas Line Valve turned
"off"
Control module in
"lockout"
Not enough gas to pilot
Low Gas Pressure
Pilot igniter/sensor is dirty
Pilot not grounded well
Draft in firebox
Pilot sensor has been bent
Pilot igniter/sensor is dirty
Pilot not grounded well
Sensor Wire loose
Gas pressure incorrect
Pilot Gas Line bent or kinked
Faulty pilot, Sensor bent
Faulty valve
Low gas pressure
Clogged or dirty carryover/burner ports
Blocked orifice
Faulty valve
Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Loose wire connections
Faulty pilot
Faulty valve
Low gas pressure
Loose sensor wire
Faulty valve
Faulty pilot or thermocouple
Clogged or dirty burner ports
(For fireplace equipped with optional ther-
mostat or thermostat remote) Room tem-
perature is higher than thermostat setting
(Optional) Remote control batteries failing
CORRECTIVE MEASURE
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
Turn shutoff valve to
"open"
Turn fireplace
"off"
and then back
Wait for pilot flame to strengthen
Check pressures. See page 12.
Clean pilot. See maintenance page 79.
Check ground connections
Vent restrictor not installed
Replace pilot
Clean flame sensor and pilot igniter. See
maintenance page 79.
Check ground connections
Check sensor wire terminals
Adjust gas pressure
Replace pilot tube
Replace Pilot
Replace Valve
Check gas supply pressure
Clean ports
Check orifice opening
Replace valve
Check gas supply pressure
Clean burner ports
Check orifice opening
Check valve/control module connections
Replace pilot
Replace valve
Check gas supply pressure
Check wire connection
Replace valve
Replace Safety pilot
Clean burner ports
Move (optional) remote away from fire-
place
Set higher temperature on (Optional)
remote/thermostat
Replace batteries in remote transmitter
and receiver
position
"on"
Page 77

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intermittent pilot dvcd fp7-4 series

Table of Contents