Empire Comfort Systems FG28BM Series Owner's Manual
Empire Comfort Systems FG28BM Series Owner's Manual

Empire Comfort Systems FG28BM Series Owner's Manual

Power-vent high-efficiency fireplace mantis
Table of Contents

Advertisement

Available languages

Available languages

EMPIRE
EMPIRE
Comfort Systems
WARNING
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instructions
are n ot f ollowed e xactly, a fi re o r e xplosion m ay r esult
causing property damage, personal injury or loss
of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
29432-1-0512
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
GLASS
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
OWNER'S MANUAL
POWER-VENT
HIGH-EFFICIENCY FIREPLACE
FG28BM(K)(N,P)-1
IG28BM(N,P)-1
Young children should be carefully supervised when
they are in the same room as the appliance. Toddlers,
young children and others may be susceptible to
accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the
house. To restrict access to a fireplace or stove,
install an adjustable safety gate to keep toddlers,
young children and other at risk individuals out of
the room and away from hot surfaces.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems FG28BM Series

  • Page 1 ™ EMPIRE EMPIRE OWNER’S MANUAL Comfort Systems WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. POWER-VENT HIGH-EFFICIENCY FIREPLACE WARNING: If not installed, operated and maintained in accordance with the manufacturer’s instructions, FG28BM(K)(N,P)-1 this product could expose you to substances in fuel IG28BM(N,P)-1 or from fuel combustion which can cause death or serious illness.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ..................3 Safety Information for Users of LP-Gas ..............4 Before You Start .......................5 Remote Set Up - Install/Replace Batteries ...............5 Remote Set Up - Set the Clock ................6 Remote Set Up - Temperature Units ................6 Remote Set Up - Programming the Remote Receiver ..........7 Starting the Fireplace - Remote ................8 Remote Operation - Manual Mode ................8...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE Safety markings are frequently used in this manual to designate a degree or level of serious- ness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if not avoided, may result in mi- nor or moderate injury or property damage. WARNING WARNING This appliance must be installed and repaired by Installation and repair should be done by a QUALI- a qualified service person who is familiar with the FIED SERVICE PERSON. The appliance should proper installation and operation of the Mantis Pow- be inspected before use and at least annually by er-Vent High Efficiency Fireplace. Installers who...
  • Page 4: Safety Information For Users Of Lp-Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS LP-Gas (Propane) is a flammable gas which can cause fires members of your household. Someday, there may not be a and explosions. In its natural state, propane is odorless and minute to lose, everyone’s safety will depend on knowing ex- colorless.
  • Page 5: Before You Start

    Before You Start If the control board LED’s do not activate, verify the fireplace is plugged in and the breaker is on. 1. Verify there is electrical power to the unit. MODE Turn on the Main Power Switch. SELECT REMOTE MANUAL MANUAL FLAME LEVEL ADJUSTMENT BLOWER FLAME SPEED LEVEL DISPLAY...
  • Page 6: Remote Set Up - Install/Replace Batteries

    Remote Set Up - Install/Replace Batteries Simultaneously press the mode and menu buttons to enter the Clock Setting Mode. The remote control receiver located in the fireplace does not use batteries. It is powered by the control board. The handheld remote is battery operated. These batter- ies will need to be replaced periodically as part of the nor- mal maintenance of the fireplace.
  • Page 7: Remote Set Up - Programming The Remote Receiver

    Remote Set Up - Programming the Remote Receiv- With the fireplace’s main electrical power switch off, set up remote per instructions on pages 5 and 6. After the remote is set up, ensure that the remote is turned on and active by hold- ing the “Power” button on the remote until the remote display panel illuminates.
  • Page 8: Starting The Fireplace - Remote

    Starting the Fireplace - Remote When the remote is activated, the fireplace display panel will illuminate and show the flame level set by the remote along The remote control has two modes for controlling the fireplace’s with the remote signal symbol. The fireplace will begin the operation - Manual and Thermostatic.
  • Page 9: Remote Operation - Thermostatic Mode

    Remote Operation - Thermostatic Mode Note: When the remote is in thermostatic mode, the fireplace will automatically adjust the flame level to meet the heat de- Turn the remote on by pressing the remote’s power button, mand from the remote. The flame level will gradually increase if the remote activates in Manual (MAN) or Thermostatic until the desired room temperature is reached, then the flame (AUTO) Mode, the fireplace will automatically start.
  • Page 10: Starting The Fireplace - Display Panel

    Fireplace Operations Sequence Starting the Fireplace – Display Panel When the main power switch is turned on, the red and green If the remote control is inoperable due to being damaged or having control board LED’s will begin to flash alternately while the dead batteries, the fireplace’s display panel may be used to oper- remote receiver searches for the remote transmitter’s signal.
  • Page 11 MODE MODE SELECT SELECT REMOTE REMOTE MANUAL MANUAL MANUAL MANUAL FLAME LEVEL FLAME LEVEL ADJUSTMENT ADJUSTMENT BLOWER FLAME BLOWER FLAME SPEED LEVEL SPEED LEVEL DISPLAY DOWN DISPLAY DOWN Mantis Mantis BACK LIGHT BACK LIGHT When a call for heat is received, the fireplace display panel Attention: The fireplace will always ignite on Level 5 (High) will illuminate and show the flame level.
  • Page 12: Turning The Fireplace Off - Remote

    Turning the Fireplace Off - Remote Turning the Fireplace Off - Display Panel When operating the fireplace using the remote, the fireplace can To turn the fireplace off from the display panel, press the “Mode be shut down by turning the thermostat temperature down (when Select”...
  • Page 13: Circulating Air Blower Operation

    Circulating Air Blower Operation Humidifier Operation The circulating air blower is operated by a temperature sensing The Mantis Power-Vent High-Efficiency Fireplace has an automat- thermistor located in the top of the fireplace. The blower will ic humidifier designed into the fireplace. As the fireplace operates, activate after approximately 3 to 5 minutes depending on condensate is created and collected inside the fireplace.
  • Page 14: Remote Functions - Sleep Timer

    Remote Functions - Sleep Timer To deactivate the Timer Mode, return to the Sleep Timer menu and set the timer to 0 (zero) minutes. Press the menu button twice to The remote is equipped with a sleep timer to automatically shut off exit the menu and save the settings. The remote’s home screen the fireplace after a certain time.
  • Page 15: Remote Functions - Pre-Set Weekly Programs

    Remote Functions - Pre-Set Weekly Programs Once the desired program is selected,press the menu button to save the setting and return to the remote’s home screen. The remote control is equipped with ten pre-set weekly operation The outline of the clock icon indicates that the program mode programs.
  • Page 16: Resetting The Fireplace

    MANUAL MANUAL If the glass needs to be replaced, contact a qualified service per- RESET FLAME LEVEL son. Only glass approved by Empire Comfort Systems Inc. can be ADJUSTMENT used, any other product will void the warranty. BLOWER FLAME SPEED LEVEL To clean inside the glass door, the door will need to be removed.
  • Page 17: Service & Maintenance

    16 and 17. If the liners need to be replaced, contact a qualified service person. Only liners provided by Empire Comfort Systems can be used, any substitute will void the warranty. Filter...
  • Page 18: Troubleshooting Lcd Codes - Normal Operation

    RECOMMENDED MAINTENANCE FREQUENCY OF MAINTENANCE MAINTENANCE ITEM MONTHLY BY ANNUALLY BY HOMEOWNER SERVICE PERSON Verify the area is free from combustible materials. Verify the combustion and ventilation air is not restricted. Verify the flue and inlet pipes do not have any cracks or holes. Verify burner flame.
  • Page 19: Troubleshooting Lcd Fault Codes On The Display Panel

    TROUBLESHOOTING LCD FAULT CODES ON THE DISPLAY PANEL FAULT LCD Digits Description ACTION DESCRIPTION Turn off main power to the fire- Yellow LED permanently OFF Anomaly as parasit- Desired flame place for 30 minutes. If problem ic flame, APT failure level is shown persists, contact a qualified or APS failure...
  • Page 20: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods specified below. Hearth products must be installed by a qualified technician and must be maintained and oper- ated safely, in accordance with the instructions in the owner’s manual.
  • Page 21 ™ EMPIRE EMPIRE MANUEL D’UTILISATION Comfort Systems FOYER HAUT RENDEMENT À ÉVACUATION FORCÉE AVERTISSEMENT : S’il n’est pas installé, utilisé et entretenu selon les instructions du fabricant, ce produit FG28BM(K)(N,P)-1 pourrait vous exposer à des substances provenant de carburant ou de sa combustion qui pourraient entrainer la IG28BM(N,P)-1 mort ou des maladies graves. Installateur : Laisser ce manuel avec l’appareil.
  • Page 22 TABLE DES MATIÈRES SECTION PAGE Informations de sécurité importantes ...............3 Informations de sécurité concernant le GPL ............4 Avant de commencer ....................5 Configuration à distance - Installer/remplacer les piles ..........5 Configuration à distance - Régler l’horloge ..............6 Configuration à distance - Unités de température ............6 Configuration à...
  • Page 23: Informations De Sécurité Importantes

    INFORMATIONS DE SÉCURITÉ IMPORTANTES CECI EST UN APPAREIL DE CHAUFFAGE Des marquages de sécurité sont fréquemment utilisés dans ce manuel pour indiquer un degré ou un niveau de gravité et ils ne doivent pas être ignorés. AVERTISSEMENT indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, peut entraîner des blessures corporelles ou la mort. ATTENTION indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, peut entraîner des blessures mineures ou modérées ou des dégâts matériels. AVERTISSEMENT AVERTISSEMENT Cet appareil doit être installé et réparé par un L’installation et les réparations doivent être effectuées technicien d’entretien qualifié qui est familiarisé par un TECHNICIEN QUALIFIÉ. L’appareil doit être avec l’installation et le fonctionnement des foyers inspecté avant utilisation et au moins une fois par an haut rendement à évacuation forcée Mantis. Les...
  • Page 24: Informations De Sécurité Concernant Le Gpl

    INFORMATIONS DE SÉCURITÉ CONCERNANT LE GPL Le GPL (propane) est un gaz inflammable pouvant provoquer des puis révisez-les point par point avec les membres de votre famille. incendies et des explosions. Dans son état naturel, le gaz propane Un jour lorsqu’il n’y aura pas une minute à perdre, la sécurité de est sans odeur et sans couleur.
  • Page 25: Avant De Commencer

    Avant de commencer Si les DEL du circuit de commande ne s’activent pas, s’assurer que le foyer est branché et que le disjoncteur est fonctionnel. 1. Vérifiez que l’appareil est alimenté. MODE Ouvrir l’alimentation principale. SELECT REMOTE MANUAL MANUAL FLAME LEVEL ADJUSTMENT BLOWER FLAME SPEED LEVEL DISPLAY DOWN Mantis...
  • Page 26: Configuration À Distance - Installer/Remplacer Les Piles

    Configuration à distance - Installer/remplacer 5. Appuyer simultanément sur les boutons mode et menu pour entrer en mode Réglage de l’horloge. les piles Le récepteur de la commande à distance situé dans le foyer n’utilise pas de piles. Il est alimenté par le circuit de commande. La commande à...
  • Page 27: Configuration À Distance - Programmer Le Récepteur À Distance

    Configuration à distance - Programmer le récepteur à distance 1. Avec l’alimentation principale fermée vers le foyer, configurer la commande à distance selon les instructions aux pages 5 et 6. Une fois la commande à distance configurée, s’assurer que la commande à distance est allumée et active en tenant enfoncé le bouton «...
  • Page 28: Démarrer Le Foyer - À Distance

    Démarrer le foyer - À distance 2. Lorsque la commande à distance est activée, le panneau d’affichage du foyer s’illuminera et affichera le niveau de flamme La commande à distance a deux modes pour contrôler le réglé par la commande à distance ainsi que le symbole signal fonctionnement du foyer - Manuel et Thermostatique.
  • Page 29: Opération À Distance - Mode Thermostatique

    Opération à distance - Mode thermostatique Remarque : Lorsque la commande à distance est en mode thermostatique, le foyer ajustera automatiquement le niveau 1. Mettre la commande à distance sous tension en appuyant sur de la flamme pour répondre à la demande de chaleur de la le bouton d’alimentation de la commande, si cette dernière commande à...
  • Page 30: Démarrer Le Foyer - Panneau D'affichage

    Séquence de fonctionnement du foyer Démarrer le foyer - Panneau d’affichage 1. Lorsque l’alimentation principale est sous tension, les voyants Si la commande à distance est ne fonctionne pas parce qu’elle DEL rouge et vert du circuit de commande commenceront à est endommagée ou que ses piles sont mortes, le panneau clignoter en alternance tandis que la commande à...
  • Page 31 MODE MODE SELECT SELECT REMOTE REMOTE MANUAL MANUAL MANUAL MANUAL FLAME LEVEL FLAME LEVEL ADJUSTMENT ADJUSTMENT BLOWER FLAME BLOWER FLAME SPEED LEVEL SPEED LEVEL DISPLAY DISPLAY DOWN DOWN Mantis Mantis BACK LIGHT BACK LIGHT 2. Lorsqu’un appel de chaleur est reçu, le panneau d’affichage Attention : Le foyer s’allumera toujours au niveau 5 (Haut) avant du foyer s’illuminera et affichera le «...
  • Page 32: Fermer Le Foyer - À Distance

    Fermer le foyer - À distance Fermer le foyer - Panneau d’affichage Lors du fonctionnement du foyer en utilisant la commande à Pour fermer le foyer à partir du panneau d’affichage, appuyer sur distance, le foyer peut être arrêté en diminuant la température du le bouton « Mode Select » (Sélection de mode) sur le panneau thermostat (lorsqu’en mode thermostatique) ou en appuyant sur le d’affichage du foyer jusqu’à...
  • Page 33: Fonctionnement De La Soufflante

    Fonctionnement de la soufflante Fonctionnement de l’humidificateur La soufflante fonctionne à partir d’une thermistance de détection Le foyer haut rendement à évacuation forcée Mantis comporte de température située au haut du foyer. La soufflante s’activera un humidificateur automatique intégré dans le foyer. Pendant que après trois à cinq minutes selon le niveau de flamme. La soufflante le foyer fonctionne, le condensat est créé...
  • Page 34: Fonctions À Distance - Minuterie Sommeil

    Fonctions à distance - Minuterie sommeil Pour désactiver le mode Minuterie, revenir au menu Minuterie Sommeil et régler la minuterie à 0 (zéro) minutes. Appuyer deux La commande à distance est équipée d’une minuterie sommeil fois sur le bouton menu pour quitter le menu et sauvegarder les pour fermer automatiquement le foyer après un certain temps.
  • Page 35: Fonctions À Distance - Programmes Hebdomadaires Préréglés

    Fonctions à distance - Programmes 4. Une fois que le programme désiré est affiché, appuyer sur le menu bouton pour sauvegarder le réglage et revenir à l’écran hebdomadaires préréglés d’accueil de la commande à distance. Le contour de l’icône commande à distance comprend programmes horloge indique que le mode programme est actif. hebdomadaires de fonctionnement préréglés.
  • Page 36: Réinitialiser Le Foyer

    « RESET » (Réinitialisation). Si la vitre doit être remplacée, contacter un technicien d’entretien MODE qualifié. Seule la vitre approuvée par l’Empire Comfort Systems SELECT Inc peut être utilisée, tout autre produit annule la garantie. Pour nettoyer la porte vitrée, la porte doit être enlevée.
  • Page 37: Service Et Entretien

    2. Relâcher les deux loquets de porte sur la partie inférieure de la Échangeur thermique chambre de combustion. L’échangeur thermique se trouve sur l’arrière du foyer. L’échangeur thermique doit être inspecté et nettoyé chaque année par un technicien d’entretien qualifié. Revêtements de foyer Avec le temps un film peut se former sur les revêtements de porcelaine.
  • Page 38: Dépannage Codes Acl - Fonctionnement Normal

    ENTRETIEN RECOMMANDÉ FRÉQUENCE D’ENTRETIEN CHAQUE OPÉRATION D’ENTRETIEN CHAQUE ANNÉE MOIS PAR LE PAR UN TECHNICIEN PROPRIÉTAIRE Vérifier l’absence de matières combustibles au voisinage. Vérifier l’absence de restriction de l’air de combustion et de ventilation. Vérifier l’absence de fissure ou perforation sur les tuyaux de fumée et d’admission. Contrôler la flamme du brûleur.
  • Page 39: Dépannage Codes De Défaillance Acl Sur Le Panneau D'affichage

    DÉPANNAGE CODES DE DÉFAILLANCE ACL SUR LE PANNEAU D’AFFICHAGE DESCRIPTION DE Chiffres Description ACTION LA DÉFAILLANCE Anomalie telle que Niveau de Fermer l’alimentation principale DEL jaune ÉTEINT en permanence flamme parasite, flamme vers le foyer pendant 30 minutes. Si panne APT ou désiré est le problème persiste, contacter un DEL vert et rouge clignotent lentement et simultanément panne APS illustré...
  • Page 40: Garantie

    GARANTIE Empire Comfort Systems Inc. garantit que ce produit à foyer est exempt de défauts au moment de son achat et pour les périodes indiquées ci-dessous. Les produits à foyer doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...

Table of Contents