Heath Zenith Secure Home DualBrite 4541 Manual page 4

Motion sensing coach light
Table of Contents

Advertisement

Available languages

Available languages

2. Stuff the wires into the junction box. Make
sure the wires from the fixture go through
the wire path, and no wires get pinched.
3. Caulk fixture mounting surface with
silicone weather sealant.
Slide the fixture onto the
mounting screws and
tighten nuts.
TESTING
1. Turn on the circuit breaker and light
switch.
Note: Sensor has a 1
riod before it will detect motion. When
first turned on, wait 1
2. Switch the on-time to TEST position and
D
B
switch to the OFF position.
®
ual
rite
TEST 1 5 10
MINUTE
Junction
Box
/
minute warm up pe-
1
2
/
minutes.
1
2
+
SEN
OFF
3 6
DUSK TO
HOUR
DAWN
Avoid aiming the control at:
• Pools of water or objects that change
temperature rapidly, such as heating vents
and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger
the control.
• Nearby large, light-colored objectsreflect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.
6 ft.
(1.8 m)
Maximum Range
The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.
Motion
Least Sensitive
3. If you need to change the sensitivity, turn
the sensitivity control on the bottom of
the cover plate.Too much sensitivity may
increase false triggering.
4. Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).
5. Set the amount of time after dusk you
want the lights on accent level.
4
30 ft.
(9.1m)
Maximum
Coverage Angle
Motion
Sensor
Most Sensitive
200257-02
180°

Advertisement

Table of Contents
loading

Table of Contents