Motor Control Module Technical Data - Graco HFR Setup And Operation

Hydraulic, plural-component, fixed-ratio proportioner.
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Motor Control Module Technical Data

Motor Control Module Technical Data
Input Specifications
Input Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input Line Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . .
Input Current per Phase . . . . . . . . . . . . . . . . . . . . . .
Maximum Branch Circuit Protection Rating: . . . . . . .
Short Circuit Current Rating . . . . . . . . . . . . . . . . . . .
Output Specifications
Output Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Line Phasing . . . . . . . . . . . . . . . . . . . . . . . . .
Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Max Ambient Temperature . . . . . . . . . . . . . . . . . . . . . . . .
Overtemperature protection is provided to protect from motor overload.
Current limit, set via the software, is provided as a secondary protection from motor overload.
All installations and wiring must comply with NEC and local electrical codes.
94
0-264 Vac, line-to-line
Single or Three Phase
50/60 Hz
25A (three-phase), 50A (single-phase)
30A (three-phase), 63A (single-phase)
5 kA
0-264 Vac
Three Phase
0-30A
200% for 0.2 seconds
24 Vdc, Class 2, Graco-provided power supply
Type 1
50°C (122°F)
313997A