Technical Data - Graco HFR Setup And Operation

Hydraulic, plural-component, fixed-ratio proportioner.
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Technical Data

Maximum Fluid Working Pressure . . . 3000 psi (20.7 MPa, 207 bar)
Maximum Fluid Temperature . . . . . . . 190°F (88°C)
Fluid Inlet Feed Pressure Range . . . . 50 psi (0.35 MPa, 3.5 bar) to 250 psi (1.75 MPa, 17.5 bar)
Fluid Inlets . . . . . . . . . . . . . . . . . . . . . Component A (Red): 1/2 npt(f)
Fluid Outlets . . . . . . . . . . . . . . . . . . . . Component A (Red): #8 (1/2 in.) JIC (3/4-16 unf), with #5 (5/16 in.) JIC adapter
Fluid Circulation Ports . . . . . . . . . . . . 1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum
Line Voltage Requirement . . . . . . . . . 230V / 1 phase and 230V / 3 phase Models: 195-264V, 50/60 Hz
Amperage Requirement . . . . . . . . . . . See Models on page 4
Sound Power . . . . . . . . . . . . . . . . . . . 93 dB
Heater Power
(A (Red) and B (Blue) heaters total,
no hose, Heated HFR Models only) . . 12 kW
Hydraulic reservoir capacity . . . . . . . . 8 gal. (30 liters)
Recommended hydraulic fluid . . . . . . Citgo A/W Hydraulic Oil, ISO Grade 46
Weight . . . . . . . . . . . . . . . . . . . . . . . . Units with 12 kW Heaters: 868 lb (394 kg)
Wetted Parts . . . . . . . . . . . . . . . . . . . Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
313997A
Component B (Blue): 3/4 npt(f)
Component B (Blue): #10 (5/8 in.) JIC (7/8-14 unf), with #6 (3/8 in.) JIC adapter
400V / 3 phase: 360-440V, 50/60 Hz
Units without heaters: 634 lb (288 kg)
fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically
resistant o-rings
Technical Data
93

Advertisement

Table of Contents
loading

Table of Contents