Main Conduit

The main conduit supplies water to the mid spray
arm, bottle wash and the upper spray system.
Main Conduit Removal
1. Remove both lower and upper racks.
2. Remove the lower spray arm.
3. Unclip the top of the conduit from the tub clip
at the tub top.
4. Remove the mid spray arm docking port by
releasing the tabs on each side of the docking
cone. The docking cone will remain attached
to the main conduit.
5. Pull the top of the conduit out of the
dishwasher to remove the bottom from the
diverter top.

Spray Arms

Lower and mid spray arms are twist lock design
and are the similar size and shape. The lower
spray arm has heat shields on the bottom and
is attached to the diverter. It is possible to
reverse the spray arms, which will result in poor
washability complaints. Care must be taken to
reassemble in the proper position. Some models
have an upper spray system which is also twist
lock.
Lower Spray Arm
The lower spray arm provides an upward directed
water flow, which turns clockwise (CW) when in
operation. The arm, bearing, and nut come as a
complete assembly and has a twist lock design.
To remove, turn the nut counter-clockwise (CCW).
Only the lower spray arm has heat shields.
Middle Spray Arm
The mid spray arm provides an upward directed
spray pattern to the upper rack. To remove the
mid spray arm, turn the nut clockwise (CW),
looking down through the upper rack.