F E A T U R E S - Kenwood CS-4125 Instruciton Manual

40/20mhz dual trace oscilloscope
Table of Contents

Advertisement

H i g h S e n s i t i v i t y
Wide B a n d s
© Continuous S w i t c h i n g
Attenuator
H i g h Speed Sweep
H i g h A c c u r a c y
L a r g e A p e r t u r e
T r a c e Rotation
Auto F r e e R u n
T e l e v i s i o n T r i g g e r
S i g n a l Selection
# O n e Touch X - Y
A u t o m a t i c T r i g g e r
S i g n a l Selection
C H I O U T P U T
V E R T M O D E T r i g g e r
F i x e d T r i g g e r i n g
A u t o m a t i c F o c u s i n g
Handle
V a r i a b l e Attenuation
Probe

F E A T U R E S

: S e n s i t i v i t y as 1 m V / d i v .
: T h e frequency band i s D C to 5 M H z C-3dB) at 1 ,
2 m V / d i v and D C to- 40MHz [ C S - 4 1 2 5 : 20MHz].
( - 3 d B ) from 5 m V / d i v .
: A. rotary s w i t c h enables v e r t i c a l a x i s s e n s i t i v i t y
to be adjusted continuously from l m V / d i v to 5 V
/ d i v .
: H i g h speed sweeping i s possible at a time base of
20 n s / d i v (during X 1 0 M A G ) .
:
A c c u r a c y is w i t h i n 3% for both v e r t i c a l a x i s s e n s i -
t i v i t y and sweep time.
: T h e 150 m m rectangular C R T monitor
an internal graticule easy v i s u a l recognition of
waveforms.
T h e waveforms displayed i n h i g h
brightness can be monitored w i t h no p a r a l l a x .
Acceleration voltage: [ C S - 4 1 3 5 : 1 2 k V , C S - 4 1 2 5 :
2 k V ] .
: T h e horizontal trace angle i s easily corrected.
T h e trace c a n be checked even w h e n there are no
trigger signals to be input.
: W i t h a specially designed c i r c u i t ,
free, stable synchronization for both frames a n d
lines c a n be realized over the whole range from
large to s m a l l amplitudes.
: S w i t c h i n g to X - Y operation at the touch of a
lever s w i t c h .
: T r i g g e r signals c a n be selected
according to the V E R T M O D E control setting by
s i m p l y s w i t c h i n g the S O U R C E control to V E R T .
: A channel 1 output t e r m i n a l has been added for
C H I input s i g n a l monitoring.
: C H I and C H 2 input signals are triggered
rately even i f they have different frequencies.
: F i x triggering exempts the user from t r o u b l e -
some triggering operations.
: Out-of-focus
i s automatically corrected
the intensity i s changed.
: A convenient handle adjustable to two tilt angles.
: T h e variable attenuation probe provides a t t e n u a -
tion at a ratio of 1 / 1 , helpful for measurement of
quite low level signals.
features
a d j u s t m e n t -
automatically
s e p a -
w h e n
7