ZONE SOUNDS AND
TIMING
( 28– 39)
DIALER
PROGRAMMING
( 40– 50)
Fields 40, 41, 42:
Enter up to the number
of digits shown. Do not
fill unused spaces.
Enter 0–9,
# + 11 for ' '
# + 12 for '#'
# + 13 for a pause
(2.5 secs)
www.PDF-Zoo.com
28
SINGLE ALARM SOUNDING PER ZONE
(Per Armed Period)
This field limits external alarm sounding to once per arming period for
a given zone. Enter 1 for yes; 0 for no.
U L
For UL installations, enter 0 for unlimited Alarm Soundings
29
FIRE SOUNDER TIMEOUT
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off. Enter 0 for sounder
timeout, or 1 for no timeout. Default is 0.
30
ALARM BELL TIMEOUT
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off. Enter as follows:
0 = No timeout; 1 = 4 min (default); 2 = 8 min; 3 = 12 min; 4 = 16 min.
38
ENTRY DELAY
System will wait the time allotted before sounding alarm upon entering.
May be selected individually
0 = 0 seconds;
4 = 60 seconds;
(EXIT delay = Entry delay plus 15 seconds).
U L
For UL installations, entry delay can be no greater than 45 seconds.
39
AUDIBLE EXIT WARNING (1-Digit Entry)
If enabled, this field provides exit warning sound when armed AWAY or
MAXIMUM.
Warning sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of Exit time.
0 = no; 1 = yes.
40
PABX ACCESS CODE (See Box at Left)
Enter up to 4 digits if PABX is needed to access an outside line. If
fewer than 4 digits are needed to be entered, exit by pressing
next field number (e.g., 41). To clear entries from field, press 40 .
41
PRIMARY PHONE No. (See Box at Left)
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
and next field number (e.g., 42). To clear entries from field, press 41 .
Note: Back-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to primary
number) is automatic only if there is a secondary phone number
(field 42).
42
SECONDARY PHONE No. (See Box at Left)
Enter up to 12 digits. If fewer than 12 digits entered, exit by pressing
and next field number (e.g., 43). To clear entries from field, press
42 . See Note in field 41 also.
Note: If you wish to send a report to a pager, see field 47 on
next page .
43
SUBSCRIBER ACCOUNT. No.
Enter digits 0–9, #+11=B, #+12=C, #+13=D, #+14=E, or #+15=F.
Enter
as the fourth digit if a 3 digit account no. (for 3+1 dialer
reporting format) is used. Enter 0 as the first digit of a 4-digit account
no. for nos. 0000–0999. End field by pressing
only 3 digits are used.
This field is also used as the Long Range Radio Subscriber Account #.
– 14 –
firealarmresources.com
(1-Digit Entry)
(1-Digit Entry)
(1-Digit Entry)
(1-Digit Entry)
1 = 20 seconds;
2 = 30 seconds;
5 = 90 seconds.
(Enter up to 4 digits).
Default is 0.
Default is 0.
Default is 1.
Default is 2.
3 = 45 seconds;
Default is 1.
and
(and press next field) if