8-4 How to check the view mode using a tact switch (cont.)
AM140/160/180/200/220/240/260/280/300KXVSSSS
Optional item
Input unit SEG1 SEG2 SEG3 SEG4
Silent mode for
Main
night-time
High-head
Main
condition setting
Long-pipng
condition
setting
(Setting
Main
is unnecessary
if high-head
condition is set)
Energy control
Individual
Operaton
Rotation defrost
Main
(HR only)
Expand
operational
temperature
Individual
range for cooling
operation
(HR only)
Channel address
Main
Snow
accumulation
Main
prevention
control
Unused option
Main
Unused option
Main
Samsung Electronics
0
0
0
1
0
2
0
7
0
3
0
4
0
5
0
6
0
0
0
1
0
8
0
2
0
3
0
0
0
1
0
9
0
2
0
0
0
1
1
0
0
2
0
0
1
1
0
1
0
0
1
2
0
1
A
U
1
3
0 ~ 15
0
0
1
4
0
1
1
5
0
0
1
6
0
0
Function of the option
Disabled (Factory default)
LEVEL 1 / Auto
LEVEL 2 / Auto
LEVEL 3 / Auto
LEVEL 1 / External contact
LEVEL 2 / External contact
LEVEL 3 / External contact
Disabled (Factory default)
Level 1 of height difference
type 1 (Indoor unit is lower
than outdoor unit)
Level 2 of height difference
type 1 (Indoor unit is lower
than outdoor unit)
Height difference type 2
(Outdoor unit is lower than
indoor unit)
Disabled (Factory default)
LEVEL 1
LEVEL 2
Basic (Factory default)
Energy saving
Power
Disabled (Factory default)
Enabled
Disabled (Factory default)
Enabled
Automatic setting
(Factory default)
Manual setting for channel
0~15
Enabled (Factory default)
Disabled
Unused option
Unused option
Remarks
Enables the silent mode
for night-time (It operates
automatically depending on
the temperature )
However, if the external
contact interface module
(MIM-B14) is used, entering
the silent mode is available
with contact signal
When outdoor unit is located
40~80m above the indoor
unit
When outdoor unit is located
over 80m above the indoor
unit
When indoor unit is over 30 m
above the outdoor unit
When equivalent length of
farthest indoor unit from
the outdoor unit is between
100~170m
When equivalent length of
farthest indoor unit from the
outdoor unit is over 170m
Energy control option
of designated operation
sequence.
※ Operating in energy
saving mode, capacity
might decrease compared
to normal operation mode.
When enabled, continuous
heating operation is possible
but heating performance
will decrease during rotation
defrost operation.
When enabled, continuous
cooling operation is possible
even in low temperature
condition up to -15°C, but
noise of the MCU will increase.
Address for classifying the
product from upper level
controller. (DMS, S-NET 3, etc )
During snow accmulation , the
fan may spin even when the
unit is not in operation.
Unused option by this model.
Unused option by this model.