Case Study - E461/361 & E464/364 & E466/366 - Samsung AM080FX A Series Service Manual

System air conditioner outdoor unit
Table of Contents

Advertisement

Troubleshooting
4-4 Case study for trouble shoots (cont.)
4-4-12 Case study – E461/361 & E464/364 & E466/366
▪ Check whether compressor defect or Inverter PBA defect.
▪ Diagnosis 1 : Using inverter checker
1. Power Off
2. Wait more than 15 minutes after the Power Off as in case of IPM failure,
discharge mode may not work properly.
3. Connect inverter checker(Phase checker)(U : RED / V : WHT / W : BLK)
4. Execute inverter checker function in OUD main PBA.
5. If any LED is not blinking → PBA defect → Change PBA
OK
Inverter PBA
st
1
visit
order
Samsung Electronics
NG
2
visit
nd
3
visit
rd
PBA replace
Check with
Order comp
Inverter checker
E461/464 / 466
E361/364 / 366
4
visit
th
Comp order
Comp replace
2
visit
nd
Comp replace
Completion
238

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents