Model Names Of Indoor/Outdoor Unit; Outdoor Unit Combination - Samsung AM080FX A Series Service Manual

System air conditioner outdoor unit
Table of Contents

Advertisement

Product Specifications

2-2 Model names of Indoor/Outdoor Unit

2-2-1 Outdoor unit combination

■ DVM S Premium compact type
System Model
Capa
Code
8HP
AM080JXVHGH/EU
10HP
AM100JXVHGH/EU
12HP
AM120JXVHGH/EU
14HP
AM140KXVGGH/EU
16HP
AM160KXVGGH/EU
18HP
AM180KXVGGH/EU
20HP
AM200KXVGGH/EU
22HP
AM220KXVGGH/EU
24HP
AM240KXVGGH/EU
26HP
AM260KXVGGH/EU
28HP
AM280KXVGGH/EU
30HP
AM300KXVAGH/EU
32HP
AM320KXVGGH1EU
34HP AM340KXVGGH1EU
36HP AM360KXVGGH1EU
38HP AM380KXVGGH1EU
40HP AM400KXVGGH1EU
42HP AM420KXVGGH1EU
44HP AM440KXVGGH1EU
46HP AM460KXVGGH1EU
48HP AM480KXVGGH1EU
50HP AM500KXVGGH1EU
52HP
AM520KXVGGH1EU
54HP AM540KXVGGH1EU
56HP AM560KXVGGH1EU
58HP AM580KXVGGH1EU
60HP AM600KXVGGH1EU
62HP AM620KXVGGH1EU
64HP AM640KXVGGH1EU
66HP AM660KXVGGH1EU
68HP AM680KXVGGH1EU
70HP AM700KXVGGH1EU
72HP
AM720KXVGGH1EU
74HP AM740KXVGGH1EU
76HP AM760KXVGGH1EU
78HP AM780KXVGGH1EU
80HP AM800KXVGGH1EU
82HP AM820KXVGGH1EU
84HP AM840KXVGGH1EU
86HP AM860KXVGGH1EU
88HP AM880KXVGGH1EU
90HP AM900KXVGGH1EU
▶ Make sure to use an indoor unit that is compatible with DVM S.
▶ Indoor units can be connected within the range indicated in following table.
▶ If the total capacity of the connected indoor units exceeds the indicated maximum capacity, cooling and heating capacity of the indoor unit may
decrease.
▶ Total capacity of the connected indoor units can be allowed from 50% to 130% of the total outdoor unit capacity.
0.5 × Σ( Outdoor unit capacity) ≤ Total capacity of the connected indoor units ≤ 1.3 × Σ( Outdoor unit capacity)
※ You can connect maximum 64 indoor units to the outdoor unit. Maximum quantity of connectable indoor unit is set to 64 since outdoor unit only
support up to 64 communication address. Indoor unit address can be assigned from 0~63.
If the indoor unit address was assigned from 64~79, E201 error will occur.
※ Maximum 32 Wall-mount type indoor units with EEV (AMSSSFNQDEHS, AMSSSJNVDKHS) can be connected.
▶ In case of combining modules more than 90HP, please consult the manufacturer when connecting the indoor unit and deciding on piping length in
accordance with design of the building.
Samsung Electronics
No. of Modules
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Capacity of Single Unit (HP)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
3
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents