Samsung AM080FX A Series Service Manual page 22

System air conditioner outdoor unit
Table of Contents

Advertisement

Product Specifications
2-2 Model names of Indoor/Outdoor Unit (cont.)
2-2-1 Outdoor unit combination (cont.)
■ DVM S Premium Energy efficiency type
System Model
Capa
Code
8HP
AM080JXVHGH/EU
10HP
AM100JXVHGH/EU
12HP
AM120JXVHGH/EU
14HP
AM140KXVGGH/EU
16HP
AM160KXVGGH/EU
18HP
AM180KXVGGH/EU
20HP
AM200KXVGGH/EU
22HP AM220KXVGGH2EU
24HP
AM240KXVGGH2EU
26HP AM260KXVGGH2EU
28HP
AM280KXVGGH2EU
30HP
AM300KXVAGH2EU
32HP AM320KXVGGH2EU
34HP AM340KXVGGH2EU
36HP AM360KXVGGH2EU
38HP AM380KXVGGH2EU
40HP AM400KXVGGH2EU
42HP AM420KXVGGH2EU
44HP AM440KXVGGH2EU
46HP AM460KXVGGH2EU
48HP AM480KXVGGH2EU
50HP AM500KXVGGH2EU
52HP AM520KXVGGH2EU
54HP AM540KXVGGH2EU
56HP AM560KXVGGH2EU
58HP AM580KXVGGH2EU
60HP AM600KXVGGH2EU
62HP AM620KXVGGH2EU
64HP AM640KXVGGH2EU
66HP AM660KXVGGH2EU
68HP AM680KXVGGH2EU
70HP AM700KXVGGH2EU
72HP AM720KXVGGH2EU
74HP AM740KXVGGH2EU
76HP AM760KXVGGH2EU
78HP AM780KXVGGH2EU
80HP AM800KXVGGH2EU
82HP AM820KXVGGH2EU
84HP AM840KXVGGH2EU
86HP AM860KXVGGH2EU
88HP AM880KXVGGH2EU
90HP AM900KXVGGH2EU
▶ Make sure to use an indoor unit that is compatible with DVM S.
▶ Indoor units can be connected within the range indicated in following table.
▶ If the total capacity of the connected indoor units exceeds the indicated maximum capacity, cooling and heating capacity of the indoor unit may
decrease.
▶ Total capacity of the connected indoor units can be allowed from 50% to 130% of the total outdoor unit capacity.
0.5 × Σ( Outdoor unit capacity) ≤ Total capacity of the connected indoor units ≤ 1.3 × Σ( Outdoor unit capacity)
※ You can connect maximum 64 indoor units to the outdoor unit. Maximum quantity of connectable indoor unit is set to 64 since outdoor unit only
support up to 64 communication address. Indoor unit address can be assigned from 0~63. If the indoor unit address was assigned from 64~79, E201
error will occur.
※ Maximum 32 Wall-mount type indoor units with EEV (AMSSSFNQDEHS, AMSSSJNVDKHS) can be connected.
▶ In case of combining modules more than 90HP, please consult the manufacturer when connecting the indoor unit and deciding on piping length in
accordance with design of the building.
Samsung Electronics
No. of Modules
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP
1
1
1
1
1
1
1
1
1
2
1
2
2
1
2
1
2
2
3
2
2
2
3
1
3
1
3
1
3
1
3
1
3
3
1
3
1
3
3
1
3
4
1
4
1
4
4
4
1
4
4
4
4
4
4
4
4
4
4
Capacity of Single Unit (HP)
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
2
1
1
2
1
1
1
2
3
2
1
3
1
3
2
4
3
2
1
3
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
3
1
1
1
2
1
1
1
1
1
1
1
1
2
17