Panasonic CT-24SL14J Service Manual page 94

Hide thumbs Also See for CT-24SL14J:
Table of Contents

Advertisement

All service adjustments are factory preset and should not require adjustment unless controls and/
or associated components are replaced.
Note:
Connect the (-) lead of the voltmeter to the appropriate ground. Use
IC801's heat sink when the HOT ground symbol is used. Otherwise,
use COLD ground (tuner shield, IC451's heat sink or FA2).
Note:
Components and test points within doted areas are located on trace
side.
B+ voltage check
1. Set the BRIGHT and PICTURE to minimum by using the PICTURE
menu.
2. Connect the DVM between C825 (+ side) or TPD14 and cold
ground.
3. Confirm that B+ voltage is 131.0V ± 2.0V. This voltage supplies B+
to the horizontal output and flyback circuits.
Source voltage chart
120V AC line input. Set the BRIGHT and the PICTURE to minimum by using the PICTURE menu.
Use cold or hot ground for the (-) lead of the DVM as needed.
Component and voltage test points
19