Panasonic CT-24SL14J Service Manual page 168

Hide thumbs Also See for CT-24SL14J:
Table of Contents

Advertisement

Equipment:
1. Isolation transformer.
2. High voltage meter.
3. D.C. Ammeter
4. Short jumper.
5. HHS jig (See figure below).
Preparation:
1. Make sure the receiver is turned off.
2. Connect the receiver to an isolation transformer.
3. Connect the ammeter serial from the flyback anode lead to the
picture tube anode socket.
4. Prepare short jumper and HHS jig.
Procedure:
1. Connect the short jumper between TPD16 & TPD17.
2. Connect the jumper diode between TPD14 and TPD15 (anode
connected to TPD15 and cathode to TPD14).
3. Apply 75VAC to AC input of isolation transformer.
4. Turn the receiver on.
5. Apply a monoscope pattern.
6. Set customer picture and brightness controls to the minimum.
7. tSet current within 50
bright controls.
Diode Connection Jumper.
A to 100
A by changing the picture and
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct-24sl14ujCt-27sl14jCt-27sl14uj

Table of Contents