- CUT B______________________02 00
- R DR_______________________07 FF
- B DR_______________________07 FF
PROCEDURE
1. Connect the oscilloscope to KG (CRT-Board).
2. In service mode for making electronic adjustment, select "BRIGH"
DAC.
3. Press RECALL button on the remote control to collapse the raster.
(service SW).
4. Connect oscilloscope to KG on C-Board and adjust service mode
"CUT-G" DAC until 170±2V above DC ground is measured
5. Remove the probe from KG.
6. Turn screen clockwise slowly until color is slightly appeared.
7. Then adjust "CUT R" and "CUT B" until line becomes white.
8. Press RECALL button on the remote to restore the raster.
9. Adjust "R DR" and "B DR" so the white seems like white and black
like black.
10. Apply a normal signal and confirm that the image is normal and a
good gray scale
11. If correction is needed perform minor touch-up method.
12.6. Deflection adjustments
To reset deflection adjustments
To reset deflection adjustments to factory adjusted default, enter to service mode (with red CHK
displayed), press POWER button on remote to display the service menu, then press and hold
28