Wall Hanging (Vertically Wall-Hanging Equipment) - Pioneer PDM-4001 Technical Manual

Table of Contents

Advertisement

Special installation (Wall hanging (vertically wall-hanging equipment))

3.4.5 Wall hanging (vertically wall-hanging equipment)

This display is designed to accommodate a range of wall installations. For this type of installation, carefully consider all
installation specifics before beginning work, since these factors can significantly affect the temperature of the air
surrounding the display. Please observe the following requirements:
1 Use plate metal that keeps all single holes clear and has dimensions no larger than those given in the following
table.
2 Leave adequate ventilation space between the wall and the display.
3 Mount a metal plate with sufficient strength at each of the four positions indicated in the following figure (four-
point stopping).
Mounting the display on the wall involves danger. Be sure to take double safety measures.
4 Recommended ambient operating temperatures are listed in the following table. Operate the display within this
temperature range.
5 The surface of the wall should closely approximate a perfectly flat plane. Keep deformation pressures on the
display, such as twisting and bending, at or below 1 mm.
Wall
Working temperature requirements
Clearance A to the wall
Less than 50 mm
50 mm or more
Less than 100 mm
Less than 100 mm
* The same conditions apply to the working temperature requirements for a speaker system (PDF-S03-LR).
3 8
Do not block this area to the left or right.
40mm
50mm
50mm
VIDEO
0~30°C
0~40°C
0~40°C
40mm
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
Machintosh (66.7Hz)
VGA (72.8Hz, 75Hz)
VGA (60Hz)
0~30°C
Not usable
0~40°C
0~30°C
0~40°C
0~35°C