This manual provides information for controlling the PDP-427CMX industrial plasma display panel
with an external communication device by using serial commands.
1
About the RS-232C Adjustment ............................................................................ 2
2
Interface .................................................................................................................. 3
3
Combination Connection ...................................................................................... 4
4
ID Assignment ........................................................................................................ 5
5
List of Commands.................................................................................................. 7
6
QUEST Commands ................................................................................................ 15
I
NDUSTRIAL
R
OMMAND
EFERENCE
Released: January 23, 2007
T
ABLE
P
LASMA
M
O
C
F
ONTENTS
D
P
ISPLAY
ANEL
ANUAL
(version 1.0)

Advertisement

loading

Summary of Contents for Pioneer PDP-427CMX

  • Page 1: Table Of Contents

    ANEL ERIAL OMMAND EFERENCE ANUAL (version 1.0) This manual provides information for controlling the PDP-427CMX industrial plasma display panel with an external communication device by using serial commands. Released: January 23, 2007 ABLE ONTENTS About the RS-232C Adjustment ................2 Interface ........................
  • Page 2: About The Rs-232C Adjustment

    RS-232C Adjustment RS-232C Adjustment This display has an RS-232C terminal. It is possible to use a PC to make various adjustments and settings. 1 About the RS-232C Adjustment Adjustments using the RS-232C: • The adjustments are written to the same memory area as for the integrator mode (refer to section 5.4.4, “PICTURE, White Balance and SCREEN Position Adjustment Values Memory Area Tables”...
  • Page 3: Interface

    RS-232C Adjustment 2 Interface 1) Connector D-sub 9 pins (male/straight) 2) Pin layout Pin No. Signal Pin No. Signal NC (not connected) NC (not connected) TxD (Transmit Data) NC (not connected) RxD (Receive Data) RTS (Request To Send) NC (not connected) NC (not connected) 3) Baud Rate 9 600 bps (standard)
  • Page 4: Combination Connection

    RS-232C Adjustment 3 Combination Connection When controlling/adjusting panels, it is convenient to connect several displays to one PC. By performing a combination connection and assigning IDs to the panels, it is possible to control and adjust several displays at the same time or separately. Connection method: Connect the panels as shown in the figure below.
  • Page 5: Id Assignment

    RS-232C Adjustment 4 ID Assignment The ID is assigned from the PC. Commands: <IDC> (ID CLEAR) ..Clears the assigned ID <IDS> (ID SET) ..... Assigns an ID IDS is only effective when an ID is not assigned. IDs are assigned starting from the panel closest to the PC. Example: Case of 4 displays (assigning IDs with the PC for the first time) First, connect an RS-232C and combination cables.
  • Page 6 RS-232C Adjustment Under the connection conditions shown below, use a combination cable for up to 16 panels. 1 Length of RS-232C cable connecting PC to Plasma Display: 5 m Conditions: 2 Combination cable length: 5 m each 3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable) For one strand, suitable for AWG28: Cross-section area = 0.08 mm ≠...
  • Page 7: List Of Commands

    RS-232C Adjustment 5 List of RS-232C Commands (Command 434CMX = Command 43MXE1 / Command 505CMX = Command 50MXE10 , 50MXE11 , 50MXE1 , 50MXE1-S / Command 425CMX = Command 42MXE10) 7 Normal Operation Related Commands Command Command Number direct Command Last 434CMX 427CMX...
  • Page 8 RS-232C Adjustment Command Command Number direct Command Last 434CMX 427CMX Function Comment 425CMX memory Effective Minimum Maximum 505CMX 507CMX Sets the MULTI SCREEN to PoutP (side by side, 2-L). MSTS06 Sets MULTI SCREEN to SWAP (switches between main – MSTS08 and sub screens).
  • Page 9 Sets the DVI BLACK LEVEL to LOW. – DBLS02 Sets the DVI BLACK LEVEL to HIGH. Note 1: The operation differs between the PDP-434CMX/PDP-505CMX and PDP-425CMX/PDP-507CMX/PDP-427CMX Note 2: EDIS01/02 only operates on the PDP-505CMX 7 “MENU”–“OPTION” related commands Command Command...
  • Page 10 RS-232C Adjustment 7 “INTEGRATOR”–“PICTURE” related commands Command Command Number direct Command Last 434CMX 427CMX Function Comment 425CMX memory Effective Minimum Maximum 505CMX 507CMX VIDEO QUALITY Adjusts the contrast. Adjusts the brightness. Adjusts the horizontal enhance. Adjusts the vertical enhance. Adjusts the color. Adjusts the tint.
  • Page 11 RS-232C Adjustment 7 “INTEGRATOR”–“OPTION” related commands Command Command Number direct Command Last 434CMX 427CMX Function Comment 425CMX memory Effective Minimum Maximum 505CMX 507CMX SCREEN MASK Displays the present set value of SCREEN MASK. FMKS00 Sets SCREEN MASK to OFF. Sets SCREEN MASK to inverse (negative – positive reversed). FMKS02 Sets SCREEN MASK to white mask.
  • Page 12 Sets sub screen translucence to 50 %. – Sets sub screen translucence to 60 %. PTRS06 – Sets sub screen translucence to 70 %. PTRS07 – Sets sub screen translucence to 80 %. PTRS08 Note 1: The operation differs between the PDP-434CMX/PDP-505CMX and PDP-425CMX/PDP-507CMX/PDP-427CMX...
  • Page 13 RS-232C Adjustment Command Command Number direct Command Last 434CMX 427CMX Function Comment 425CMX memory Effective Minimum Maximum 505CMX 507CMX – BPIS01 Sets the BANNER PinP input to INPUT1. Sets the BANNER PinP input to INPUT2. – BPIS02 Sets the BANNER PinP setting to OFF. –...
  • Page 14 RS-232C Adjustment Command Command Number direct Command Last 434CMX 427CMX Function Comment 425CMX memory Effective Minimum Maximum 505CMX 507CMX – – RMCS26 Remote control key: POINT ZOOM – – RMCS27 Remote control key: ID NO SET – – RMCS28 Remote control key: CLEAR –...
  • Page 15: Quest Commands

    RS-232C Adjustment 6 QUEST Commands What are QUEST commands? • Quest commands output TXD such as adjustment data from the panel’s microprocessor to a PC. • Adjustment and other data is output in ASCII code. Note Command names are given inside brackets < >. •...
  • Page 16 RS-232C Adjustment 1) Obtaining QST Status Information Sequence Data Content Size Remarks 1 Byte 02hex Command echo-back 3 Byte QST (fixed) Generation information 1 Byte 5 (fixed) Inch information 1 Byte 4: 42 inch 5: 50 inch Forwarding 1 Byte M (fixed) Power source state 1 Byte...
  • Page 17 RS-232C Adjustment 2) <QPI> Obtaining Integrator/PICTURE information Sequence Data Content Size Remarks 1 Byte 02hex Command echo-back 3 Byte QPI (fixed) CONTRAST 3 Byte 000 to 255 Note 1) BRIGHTNESS 3 Byte 000 to 255 Note 1) C,DETAIL R (RED) 3 Byte 000 to 060 Note 1) C,DETAIL Y (YELLOW)
  • Page 18 RS-232C Adjustment 5) <QSS> Obtaining SETUP information Sequence Data Content Size Remarks 1 Byte 02hex Command echo-back 3 Byte QSS (fixed) COLOR TEMP. 1 Byte 1: LOW 2: MID LOW 3: MIDDLE 4: MID HIGH 5: HIGH Note 1) POWER MGT. 1 Byte 0: OFF 1: ON...
  • Page 19 RS-232C Adjustment Sequence Data Content Size Remarks PRO USE UNDERSCAN 1 Byte 0: OFF 1: ON PRO USE IMAGE PROCESS 1 Byte 1: NORMAL 2: PURE 3: MONOTONE 4: BLUE ONLY 5: HIGH CONTRAST PRO USE SYGNAL TYPE 1 Byte 1: MOTION 2: STILL 3: NONE STD 1 Byte 0: OFF...
  • Page 20 Command echo-back 3 Byte QAP (fixed) Machine name information 18 Byte 42 inch: A (North America model): PDP-427CMX******** G (Europe-general model): PDP-42MXE20******* 50 inch: J (Japan model): PDP-507CMX-JP***** A (North America model): PDP-507CMX******** G (Europe-general/CKD model): PDP-50MXE20******* GS (Europe-general/silver model): PDP-50MXE20*******...
  • Page 21 RS-232C Adjustment 7 Table of commands not compatible with PDP-434CMX to PDP-425CMX Ends 232C integrator adjustment mode. Turns off MASK CONTROL. Starts 232C integrator adjustment mode. Turns on MASK CONTROL. Displays present color off setting. MGFS01 Turns on VIDEO WALL. COFS00 Does not set color off.
  • Page 22 RS-232C Adjustment 7 Check Sum This is data to which 2-Byte ASCII code is added to a data group returned by a QUEST command. PC side QUEST command 02 (hex) 2 Byte 3 Byte 03 (hex) Set side QUEST command Data Check sum 02 (hex)