Product Description And Electrical Requirements - Scotsman C1848R Installation And User Manual

Remote condenser modular cuber
Hide thumbs Also See for C1848R:
Table of Contents

Advertisement

C1448, C1848, C2148 E Series
Remote Condenser Models - User Manual

Product Description and Electrical Requirements

Dimensions
Model
w" x d" x h"
48 x 24 x 29
C1448SR-32
same
C1448SR-3
same
C1448MR-32
same
C1848SR-32
same
C1848MR-32
same
C1848SR-3
same
C2148SR-3
same
C2148MR-3
*Or HACR circuit breakers.
Table notes: Series revision code omitted. All the
listed condensers include a headmaster valve.
Ratings include the remote condenser motor, as it
is designed to be powered by the ice machine. If
connecting remote condenser independently of the
ice machine, use the information on the condenser's
dataplate for fuse and wire sizes.
Central Condenser (Rack) Coils
The ice machine may be connected to a central
condenser coil. The requirements are:
• Coil – not previously used with mineral oil system.
Virgin coil preferred.
• Correct size (internal volume) and capacity (BTUH).
• Includes a headmaster valve for discharge pressure
control. Headmaster kit available for certain MAC
condensers, kit number is RCKCME6GX.
Note: Do not use C1848R or C2148R with MAC
• Fan motor on all the time or controlled to be on
whenever the ice machine is operating.
• U.L. listed for the ice machine
• Non-Scotsman condensers must have prior
Scotsman Engineering approval for warranty
coverage to be in effect.
Electrical
Use
condenser
208-230/60/1
ERC311-32
208-230/60/3
ERC311-32
208-230/60/1
ERC311-32
208-230/60/1
ERC611-32
208-230/60/1
ERC611-32
208-230/60/3
ERC611-32
208-230/60/3
ERC611-32
208-230/60/3
ERC611-32
January 2009
February 2016
Page 4
Minimum
Circuit
Ampacity
17.0
12.9
17.0
17.8
17.8
13.4
21.5
21.5
Refrigerant tubing kits:
The ice making head's and the remote condenser's
refrigeration circuits must be connected. They are
designed to be connected Scotsman refrigerant
tubing, supplied in kits of liquid and discharge tubes.
Several lengths are available, order the one that just
exceeds the length needed for the site.
10'
25'
C1448,
BRTE10 BRTE25 BRTE40 BRTE75
C1848,
C2148
No additional refrigerant is required.
Maximum
Suggested
Fuse* Size
Fuse* Size
30
20
30
15
30
20
20
20
20
20
20
20
30
30
30
30
40'
75'