C0322 through C1030
Air and Water Cooled User Manual
Product Description & Electrical Requirements
Dimensions
Model
w" x d" x h"
C0322SA-1
C0322SW-1
C0322SA-32
C0322SW-32
22.75** x 24 x 23
C0522SA-1
C0522SW-1
C0522SA-32
C0522SW-32
C0330SA-1
C0330SW-1
C0330SA-32
C0330SW-32
C0530SA-1
30.75** x 24 x 23
C0530SW-1
C0530SA-32
C0530SW-32
C0630SA-32
C0630SW-32
C0830SA-32
C0830SW-32
C0830SA-3
C0830SW-3
30.75** x 24 x 29
C1030SA-32
C1030SW-32
C1030SA-3
C1030SW-3
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision
code omitted.
* Or HACR type circuit breakers.
** Maximum width at top panel. Air cooled models add .75" for left side louvers.
Electrical
Condenser
volts/Hz/phase
115/60/1
Air
115/60/1
Water
208-230/60/1
Air
208-320/60/1
Water
115/60/1
Air
115/60/1
Water
208-230/60/1
Air
208-230/60/1
Water
115/60/1
Air
115/60/1
Water
208-230/60/1
Air
208-230/60/1
Water
115/60/1
Air
115/60/1
Water
208-230/60/1
Air
208-230/60/1
Water
208-230/60/1
Air
208-230/60/1
Water
208-230/60/1
Air
208-230/60/1
Water
208-230/60/3
Air
208-230/60/3
Water
208-230/60/1
Air
208-230/60/1
Water
208-230/60/3
Air
208-230/60/1
Water
July 2006
Page 4
Minimum
Maximum
Circuit
Fuse Size*
Ampacity
12.7
15
11.9
15
6.1
15
5.6
15
13.8
15
12.2
15
7.6
15
6.7
15
12.7
15
11.9
15
6.1
15
5.6
15
13.9
15
12.2
15
7.9
15
6.7
15
18.2
20
17
20
10.2
15
9
15
8.4
15
7.2
15
16
20
14.8
15
11
15
9.8
15