Scotsman C1448R Installation And User Manual

Hide thumbs Also See for C1448R:

Advertisement

Installation and User's Manual
Models C1448R, C1848R, C2148R

Advertisement

Table of Contents
loading

Summary of Contents for Scotsman C1448R

  • Page 1 Installation and User’s Manual Models C1448R, C1848R, C2148R...
  • Page 2: Table Of Contents

    C1448, C1848, C2148 Remote Condenser Models - User Manual Introduction The design of this modular remote cuber is the result The Installation section provides the trade person with of years of experience with remote ice machine the information needed to properly install and start refrigeration systems.
  • Page 3: Installation: Product Specifications

    C1448, C1848, C2148 Remote Condenser Models - User Manual Installation: Product Specifications Location Limitations The warranty statement for this product is provided separately from this manual. Refer to it for applicable This ice system is made up of three parts, the ice coverage.
  • Page 4: Model Number Description

    Scotsman. • 32=Electrical code. -32=208-230/60/1, -3= 208- 230/60/3 Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and • B=series revision code. B=2nd series. design are subject to change without notice.
  • Page 5: Product Description And Electrical Requirements

    RCKCME6GX. • Fan motor on all the time or controlled to be on whenever the ice machine is operating. • U.L. listed for the ice machine • Non-Scotsman condensers must have prior January 2009 November 2006 Page 4...
  • Page 6: Condenser And Machine Layouts

    C1448, C1848, C2148 Remote Condenser Models - User Manual Condenser and Machine Layouts .88 DIA. ELECTRICAL 29.50 in INLET 74.9 cm DISCHARGE LINE 1/2" MALE CPLG. 2.75 LIQUID LINE 3/8" MALE CPLG. 38.47 in 97.7 cm Cond. Fins 32.32 in 82.1 cm 35.72 in 90.7 cm...
  • Page 7: Water

    A triple head filter is recommended. Either the In addition, this product is designed to automatically Scotsman SSM3 taste and odor filter system, or the vary the amount of water purged based on the purity ADS-AP3 AquaPatrol system.
  • Page 8: Panel Removal

    C1448, C1848, C2148 Remote Condenser Models - User Manual Panel Removal 1. Locate and loosen the two screws at the front edge of the top panel. 2. Pull the front panel out at the top until it clears the top panel. 3.
  • Page 9: Remote Condenser Location

    Use the following for planning the placement of the Configurations that do NOT meet these requirements condenser relative to the ice machine must receive prior written authorization from Scotsman. Location Limits - condenser location must not exceed ANY of the following limits: Do NOT: •...
  • Page 10: For The Installer: Remote Condenser

    C1448, C1848, C2148 Remote Condenser Models - User Manual For The Installer: Remote Condenser Locate the condenser as near as possible to the Roof Attachment interior location of the ice machine. Install and attach the remote condenser to the roof Note: The location of the condenser is relative to the of the building, using the methods and practices of ice machine is LIMITED by the specification on the...
  • Page 11: Precharged Line Routing

    C1448, C1848, C2148 Remote Condenser Models - User Manual Precharged Line Routing Do not connect the precharged tubing until all routing 2. Have the roofing contractor cut a minimum hole for and forming of the tubing is complete. See the the refrigerant lines of 1 3/4”.
  • Page 12: Coupling Instructions

    C1448, C1848, C2148 Remote Condenser Models - User Manual Coupling Instructions The couplings on the ends of the pre-charged line It is important that ONLY the nut on the pre-charged sets are self-sealing when installed properly. tube be turned, or the diaphragms will be torn out by the piercing knives and they will be loose in the Follow these instructions carefully.
  • Page 13: Plumbing Requirements

    C1448, C1848, C2148 Remote Condenser Models - User Manual Plumbing Requirements All models require connection to cold, potable water. Water Filters A hand actuated valve within site of the machine Install a new cartridge if the filters were used with a is required.
  • Page 14: Drains

    C1448, C1848, C2148 Remote Condenser Models - User Manual Drains All models require drain tubing to be attached to them. the drain, extended about 8 – 10” will allow the gravity There is a single ¾” FPT drain fitting in the back of the drain to empty and also keep any surges during cabinet.
  • Page 15: Electrical

    C1448, C1848, C2148 Remote Condenser Models - User Manual Electrical The machine is not supplied with a power cord, the 1. Remove the junction box cover and route the machine must be hard-wired. power cord through the access hole and properly attach the power supply wires to the leads in the The dataplate on the back of the cabinet details junction box.
  • Page 16: Final Check List

    C1448, C1848, C2148 Remote Condenser Models - User Manual Final Check List: 1. Is the unit located indoors in a controlled environment? 2. Is the condenser located where it can receive adequate cooling air? 3. Has the correct electrical power been supplied to the machine? 4.
  • Page 17: Initial Start Up

    OFF when returned to its Model F. cond air F. cond air normal position. F. water F. water C1448R 14-15 Note: Moving the curtain during the Freeze cycle has no affect on unit operation. C1848R 9-10 C2148R 8.
  • Page 18: Adjustments

    C1448, C1848, C2148 Remote Condenser Models - User Manual Adjustments Bridge Thickness - For A Service Tech Only 1/8 - 3/16” bridge 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove left curtain. 4. Use a box wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness.
  • Page 19: Use And Operation

    If the Clean light is on, the machine has determined that it may need to be cleaned. Contact an authorized Scotsman service agent and have the machine cleaned, de-scaled and sanitized. November 2006 Page 18...
  • Page 20: Switches

    C1448, C1848, C2148 Remote Condenser Models - User Manual Switches The two switches – on and off - can be accessed from the front of the machine. 02-4294-01 Graphic Rev. B To switch the machine OFF, push and release the Off Full Rotate knob to set ice level Yellow Arrow = Max Ice...
  • Page 21: Options And Other Information

    C1448, C1848, C2148 Remote Condenser Models - User Manual Options and Other Information Smart-Board the bin. When removing ice, tap the groups of ice with an ice scoop to separate them into smaller units. In a When this option is present there is an additional dispenser, this ice will break up into mostly individual display panel in the area below the main control cubes as the dispense mechanism moves the ice.
  • Page 22: Cleaning, Sanitation And Maintenance

    Go onto the next step when the purge valve light pivot pin to release it. Pull curtains out of machine goes out. 6. Pour 24 ounces of Scotsman Clear 1 Scale Remover into the reservoir. Push Here 7. Allow the ice machine cleaner to circulate in the water system for at least 10 minutes.
  • Page 23 Inspect each distributor for restricted orifice holes. mixing 1 packet of Stera Sheen Green Label sanitizer Be sure all holes are full open. (available from Scotsman) with 2 gallons of warm (95- F.) potable water. Squeeze tabs together, slide out until it stops, then lift 17.
  • Page 24: Remote Condenser

    C1448, C1848, C2148 Remote Condenser Models - User Manual Remote condenser The condenser fins will need to be cleaned. Push and release the Off button. Wait until the machine stops. Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart.
  • Page 25: What To Do Before Calling For Service

    C1448, C1848, C2148 Remote Condenser Models - User Manual What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. • High discharge temperature. •...
  • Page 26 SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com 17-3083-04 Rev D. Print Rev E...

This manual is also suitable for:

C1848rC2148r

Table of Contents