Raid Setup Using Raid Bios - Bosch DIVAR IP 6000 Series Installation Manual

Hide thumbs Also See for DIVAR IP 6000 Series:
Table of Contents

Advertisement

28
en | RAID setup
See also
6.2

RAID setup using RAID BIOS

To configure the hard drive using RAID BIOS:
1.
2.
3.
4.
5.
6.
7.
8.
See also
2016.08 | V2.1 | DOC
Setting the IP address, page 25
Install all hard drives.
Turn on the system and press Ctrl+R when MegaRAID Configuration Utility is displayed
on the screen. The display appears before Windows starts.
In the MegaRAID Configuration Utility program, select Create Virtual Drive.
Apply the following settings:
RAID Level: RAID-5
Under Advanced settings:
Strip Size: 64KB
Write Policy: Write Back
Note: All other settings remain unchanged.
Select all hard drives that are part of the RAID group.
Start the virtual drive initialization.
Exit the MegaRAID Configuration Utility program.
Perform a complete system recovery (Initial Factory Setup).
Recovering the unit, page 29
Installation Manual
DIVAR IP 6000 (3U)
Bosch Sicherheitssysteme GmbH

Advertisement

Table of Contents
loading

Table of Contents