Basket Lift Problems; Filtration Problems - Frymaster FilterQuick 5FQG30U Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

6.2.3 Basket Lift Problems

PROBLEM
Basket lift movement is
jerky and/or noisy.

6.2.4 Filtration Problems

PROBLEM
Fryer filters after each
Filter prompt setting incorrect.
cook cycle.
Filter menu functions
won't start or
controller displays
WAIT FOR
Filter .
Controller displays
Another function is in process or the
FLT DYLD or
filter has been bypassed.
POL dlyd.
Filter pump won't
start or pump stops
during filtering.
Filter Pump runs, but
oil return is very slow.
Controller displays
OIL IN DRAIN
PAN / CONFIRM
Drain valve or return
valve stays open.
Controller displays
INSERT pan.
PROBABLE CAUSES
Basket lift rods need lubrication.
PROBABLE CAUSES
A.
Temperature too low or
controller displays OFF.
B.
Another function is still in
process.
C.
MIB has not cleared checking
system.
D.
Messages or errors on other
controllers.
E.
Filter pan not fully engaged.
A. Power cord is not plugged in or
circuit breaker is tripped.
B. Pump motor has overheated
causing the thermal overload
switch to trip.
C. Blockage in filter pump.
A. Improperly installed or prepared
filter pan components or cold oil.
Drain valve open or possibility that
oil is in drain pan.
A. AIF board has failed.
B. Actuator has failed.
A. Filter pan is not fully set into
fryer.
B. Missing filter pan magnet.
C. Defective filter pan switch.
CORRECTIVE ACTION
Apply a light coating of Lubriplate
lightweight white grease to the rod and bushings.
CORRECTIVE ACTION
Change the filter prompt setting.
A. Ensure fryer is at setpoint before starting;
ensure the controller is ON.
B. Wait until the previous function ends to start
another filtration cycle.
C. Wait one minute and try again.
D. Clear messages and errors on other controllers.
E. Ensure the filter pan is in position and fully
inserted into the fryer and "A" is displayed on
the MIB board.
Wait until the previous function ends to start
another filtration cycle or select "YES" to "FILTER
NOW?" if present on another controller.
A. Verify that the power cord is fully plugged in
and the circuit breaker is not tripped.
B. If the motor is too hot to touch for more than a
few seconds, the thermal overload switch has
probably tripped. Allow the motor to cool at
least 45 minutes then press the Pump Reset
Switch (see page 4-3).
C. Call your FAS for assistance.
A. Remove the oil from the filter pan and
replace the filter paper, ensuring that the filter
screen is in place under the paper.
Verify that O-rings are present and in good
condition on filter pan connection fitting.
Press  (CONFIRM) and follow directions for
FILL VAT FROM DRAIN PAN.
Call your FAS for assistance.
A. Pull filter pan out and fully reinsert into fryer.
B. Ensure the filter pan magnet is in place and
replace if missing.
C. If the filter pan magnet is fully against the
switch and computer continues to display
INSERT pan, switch is possibly defective.
6-4