Problem
FQ4000 displays
TEMPERATURE PROBE
FAILURE.
Heating indicator is on,
but fryer is not heating.
FQ4000 displays RECOVERY
FAULT and alarm sounds.
FQ4000 displays NO MENU
GROUP AVAILABLE FOR
SELECTION
FQ4000 displays SERVICE
REQUIRED followed by an
error message.
6.2.3

Basket Lift Problems

PROBLEM
Basket lift movement is
jerky and/or noisy.
6.2.4

Filtration Problems

Problem
Fryer filters after each
cook cycle.
Clean and Filter won't
start.
FQ4000 display shows
FILTER BUSY.
Filter pump won't start, or
pump stops during
filtering.
Drain valve or return valve
stays open.
Probable Causes
Problem with the temperature measuring
circuitry including the probe or damaged
controller wiring harness or connector.
Three phase power cord unplugged, or circuit
breaker is tripped.
Recovery time exceeded maximum time limit.
All menu groups have been deleted.
An error has occurred which requires a service
technician.
PROBABLE CAUSES
Basket lift rods need lubrication.
Probable Causes
Filter after setting incorrect.
Temperature too low.
A.
Another filtration cycle or filter pad change
is still in process.
B.
Filter interface board has not cleared
checking system.
A.
Power cord is not plugged in or circuit
breaker is tripped.
B.
Pump motor has overheated causing the
thermal overload switch to trip.
C.
Blockage in filter pump.
A.
VIB board has failed.
B. Actuator has failed.
Shut the fryer down and call your FAS for
assistance.
Verify that all power cord(s) are fully seated in
their receptacle(s), locked into place and that
circuit breaker is not tripped If the problem
continues call your FAS for assistance.
Clear error and silence the alarm by pressing the
√ button. Maximum recovery time for electric is
1:40. If this error continues call your FAS for
assistance.
Create a new MENU group. Once a new menu is
created, add recipes to the group (see section
1.10 of the FQ4000 controller manual).
Press X to continue cooking and call your FAS for
assistance. In some cases, cooking may not be
available.
CORRECTIVE ACTION
Apply a light coating of Lubriplate
white grease to the rod and bushings.
Change or overwrite the filter after setting by
re-entering the filter after value in Manager
Settings, Filter Attributes in section 1.8 of the
FQ4000 controller manual.
Ensure fryer is at setpoint before starting a
Clean and Filter.
A.
Wait until the previous filtration cycle
ends to start another filtration cycle.
Change filter pad if prompted.
B.
Wait 15 minutes and try again.
A.
Verify that the power cord is fully plugged
in and the circuit breaker is not tripped.
B.
If the motor is too hot to touch for more
than a few seconds, the thermal overload
switch has probably tripped. Allow the
motor to cool at least 45 minutes then
press the Pump Reset Switch (see section
2.1.2 of the FQ4000 controller manual).
C.
Call your FAS for assistance.
Call your FAS for assistance.
6-4
Corrective Action
or similar lightweight
Corrective Action

Hide quick links:

Advertisement

Table of Contents