Power Specifications

Input Power
Output Power
48
Gemini GT6 Hardware Installation Guide
AC
Drive
AC Input Range
GT6-L5
95VAC – 132VAC, 50/60 Hz, single phase
GT6-L8
95VAC – 132VAC, 50/60 Hz, single phase
GT6-U5
95VAC – 132VAC and 190VAC – 264VAC, 50/60 Hz, single phase
GT6-U8
95VAC – 132VAC and 190VAC – 264VAC, 50/60 Hz, single phase
Connector
Drive connector:
#8 (M4) screw terminals.
Mating terminals:
spade fork, 0.325" maximum width
Do not operate GT6-U5/8 in the 132VAC – 190VAC range, or the drive will be
You must connect V DBL to L2/N on GT6-U5/8 to enable the voltage doubler for
Do not operate GT6-L5/8 above 132VAC, or the drive will be
+24VDC "Keep Alive" Power
Input voltage range:
Input current:
Output Current
Drive
(amps, peak)
GT6-U5
5.0
GT6-U8
7.5
GT6-L5
5.0
GT6-L8
8.0
Connector
Drive connector:
#8 (M4) screw terminals.
Mating terminals:
spade fork, 0.325" maximum width
CAUTION
permanently damaged.
CAUTION
120VAC operations.
CAUTION
permanently damaged.
19.2 – 28.8 VDC
500 mA (maximum)
Output Voltage (motor bus)
(DC, rms)
74
74
170
170