Run Capacitor; Start Capacitor And Start Relay - Henny Penny BCM-110 Technical Manual

Blast chiller/freezer
Hide thumbs Also See for BCM-110:
Table of Contents

Advertisement

2-15. RUN CAPACITOR

Run Capacitor
2-16. START CAPACITOR AND
START RELAY
Start Relay
Start Capacitor
2-8
1. Remove the electrical power to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Remove the two screws securing the front panel and pull
down the panel.
3. Bend out the clips securing the rodent cover on the back of
the unit, and pull the cover down.
4. Using a Phillips head screwdriver, remove the two screws
securing the cover of the junction box, and remove the cover.
5. Disconnect the wires from the relay to the capacitor.
6. Remove the capacitor from the unit, from the front.
7. Install new capacitor in reverse order.
1. Remove the electrical power to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Bend out the clips securing the rodent cover on the back of
the unit, and pull the cover down.
3. Using a Phillips head screwdriver, remove the two screws
securing the cover of the junction box, and remove the cover.
(See section 2-12 above).
4. Disconnect the wires to either the relay or the capacitor, and
remove component from the unit.
5. Install new component in reverse order.
Model BCF-24/65/110, BCM-110
603

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcf-65Bcf-110Bcf-24

Table of Contents