Fuse And Fuse Holder; Condensation Evaporator - Henny Penny BCM-110 Technical Manual

Blast chiller/freezer
Hide thumbs Also See for BCM-110:
Table of Contents

Advertisement

2-12. FUSE AND FUSE
HOLDER
Fuse Holder
2-13. CONDENSATION
EVAPORATOR
2-6
If the unit has no power, the fuse may be blown. To access the
fuse:
1. Remove the electrical power to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Remove the two screws securing the front panel and pull
down the panel.
3. Unscrew the fuse cap and pull the 10 amp fuse from the
holder.
To check and replace the fuse holder:
1. Remove the two screws securing the front panel and pull
down the panel.
2. Remove the two bolts securing the control box and pull the
control box from the unit. (See Control Board Section.)
3. Remove the four screws securing box top and remove the top.
4. Remove the wires from the fuse holder and check for conti-
nuity across the terminals. The circuit should show closed.
If open, replace fuse holder.
5. Reinstall the control box and front panel, and unit is now
ready for use.
1. Remove electrical power to unit and allow evaporator to cool.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
Also, if evaporator is functional, it will be very hot! Allow
evaporator to cool before removing, or burns could result.
Model BCF-24/65/110, BCM-110
603

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcf-65Bcf-110Bcf-24

Table of Contents