Step 4. FIELD WIRING
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peu-vent entraîner un fonctionnement inadéquat
et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-quatement une fois
l'entretien terminé.
CAUTION: Ground supply lead must be connected to the wire
attached to the green ground screw located on the outlet box.
See Figures 32 and 33 on Page 24. Failure to do so will result
in a potential safety hazard. The appliance must be electrically
grounded in accordance with local codes or, in the absence of
local codes, the National Electrical Code, ANSI/NFPA 70-latest
edition (In Canada, the current CSA C22.1 Canadian Electrical
Code).
14 Gage
Grounded
Romex
Strain
Relief
Vacuum
Hose
Snap
Bushing
Wall Switch
Harness
Figure 25
Adaptor Assembly
*See Figure 15 on Page 15.
Figure 26 - Vacuum Hose Connection To Probe
22
Right Side
of Fireplace
Junction Box
Probe (1 *)
Hose Clamp (7 *)
Vacuum Hose (2 *)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Route Wiring
NOTE: Electrical wiring must be performed by a qualified electrician.
• Install the strain relief in the hole provided on the right side of fireplace
for the electrical wiring (refer to Figure 25).
Standard Instruction (For use when access to the termination is
difficult because of height or other reasons).
• Locate a locally procured electrical junction box within reach of the
termination wiring pigtail (refer to Figure 28 on Page 23) and route
the pigtail to the junction box as the termination is installed.
• Route 14 gauge AWG grounded Romex wiring (not provided) from
the fireplace to the just installed junction box close to the termina-
tion. Ensure the wiring is safety plated to prevent damage by framing
nails and finish drywall screws. Route the wire into the lower control
compartment and cut to length before installing the terminals. Install
provided wiring hardware on the ends of the Romex wire.
• Refer to Figure 29 on Page 23 and install the electrical hardware on
the ends of the Romex wiring. Male terminals on the Black and White
wires, and ring terminals on the ground wire.
• Using standard electrical practices and the terminals provided, con-
nect the three wires of the Romex cable to the termination pigtail
within the Electrical junction box. Ensure ground.
• The fireplace end of the Romex will be addressed in Connecting The
Power Vent To The Fireplace Control System.
Vacuum Hose
Pressure switch is located
behind the panel on the right
side of firebox
Vacuum Hose
Pressure Switch
Figure 27 - Vacuum Hose Connection To Pressure Switch
Installation Instructions
900358-00, 01/2018
Pressure Switch