Misc. Codes/Standards; Inputs And Efficiencies; Gas Valve Diagram; Massachusetts Requirements - Superior Fireplaces DRT63 Installation & Operation Instructions

See-through direct-vent gas fireplaces with power-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT63STTYN Power-Vent Direct-Vent Fireplaces
WARNING
Improper installation, adjust-
ment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualified installer, service
agency or the gas supplier.
WARNING
Failure to comply with these
installation instructions will result
in an improperly installed and
operating appliance, voiding its
warranty. Any change to this appli-
ance and/or its operating controls
is dangerous.
WARNING
Clothing or other flammable
material should not be placed
on or near the appliance.
AVERTISSEMENT
On ne devrait pas placer de
vêtements ni d'autres matières
inflammables sur l'appareil ni à
proximité.
WARNING
Any safety screen or guard
removed for servicing the appli-
ance must be replaced prior to
operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré
pour permettre l'entretien de
l'appareil doit être remis en
place avant de mettre l'appareil
en marche.
WARNING
Improper installation or use of
this appliance can cause serious
injury or death from fire, burns,
explosion or carbon monoxide
poisoning.
NOTE: Installation and repair should be done
by a qualified service person. The appliance
should be inspected before use and at least
annually by a professional service person.
More frequent cleaning may be required due
to excessive lint from carpeting, bedding
material, etcetera. It is imperative that control
compartments, burners and circulating air
passageways of the appliance be kept clean.
Remarque : L'installation et la répara-
tion devrait être confiées à un technicien
qualifié. L'appareil devrait faire l'objet
d'une inspection par un technicien profes-
sionnel avant d'être utilisé et au moins
une fois l'an par la suite. Des nettoyages
plus fréquents peuvent être nécessaires si
les tapis, la literie, et cetera produisent
une quantité importante de pous-sière.
Il est essentiel que les compartiments
abritant les commandes, les brûleurs
et les conduits de circulation d'air de
l'appareil soient tenus propres.
Do not use these appliances if any part
has been under water. Immediately call a
qualified, professional service technician to
inspect the appliance and to replace any parts
of the control system and any gas control
which have been under water.
Ne pas utiliser cet appareil s'il a été
plongé, même partiellement, dans
l'eau. Appeler un technicien qualifié pour
inspecter l'appareil et remplacer toute
partie du système de commande et toute
commande qui a été plongée dans l'eau.
Only trim kit(s) supplied by the manufacturer
shall be used in the installation of this ap-
pliance.
Seules les trousses de garniture fournies
par le fabricant doivent être utilisées pour
l'installation de cet appareil.
These appliances comply with National Safety
Standards and are tested and listed by PFS
(Report No. F14-107) to ANSI Z21.88 (in
Canada, CSA-2.33), and CAN/CGA-2.17-M91
(CSA P4.1) in both USA and Canada, as a
vented gas fireplace.
These appliances comply with CSA P.4.1-2015
"Testing Method for Measuring Annual Fireplace
Efficiency. P4 (EnerGuide) is a measurement of
the Canadian Office of Energy Efficiency.
Based on CSA P.4.1-2015
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900358-00, 01/2018
These appliances are listed by Intertek for
installation in bedrooms, aftermarket mobile
homes, and manufactured homes.

Misc. Codes/Standards

Installation must conform to local codes or, in
the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest
edition (in Canada, the current CAN/CGA-B149.1
installation code).
The appliance, when installed, must be electri-
cally grounded and wired in accordance with
local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA
70 - latest edition, or the Canadian Electrical
Code, CSA C22.1 - latest edition.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front or back openings of the appliance.
These appliances are designed to operate on
natural or propane gas only (if field-converted
to propane). The use of other fuels or combi-
nation of fuels will degrade the performance
of this system and may be dangerous.
The system is switchable between standing
and intermittent pilot modes. External electrical
power is required to operate these units.
These models come standard with a remotely
modulated gas valve. The included transmitter
remotely controls flame appearance and heat
output (manual gas valve adjustment is not
possible).

Inputs and Efficiencies

Appliance BTU inputs are listed in Table 1A.
Appliance efficiencies are listed in Table 1B.
INPUTS
Gas Type
Natural Gas
40,000 to 60,000
Liquid Propane
43,500 to 56,000
(field-converted to LP)
Table 1A
EFFICIENCIES
Gas Type
AFUE
Natural Gas
68%
Table 1B
Inputs
BTU/hr
BTU/hr
EnerGuide
62%
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drt63sttyn

Table of Contents