OPERATION AND CARE OF YOUR APPLIANCE

Young children should be carefully supervised when they are in the
same room as the appliance. Toddlers, young children and others
may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
Les jeunes enfants devraient être surveillés étroitement lorsqu'ils se trou-
vent dans la même pièce que l'appareil. Les tout petits, les jeunes enfants
ou les adultes peuvent subir des brûlures s'ils viennent en contact avec
la surface chaude. Il est recommandé d'installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher l'accès
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure
empêchera les tout petits, les jeunes enfants et toute autre personne à
risque d'avoir accès à la pièce et aux surfaces chaudes.
Appliance Operation
Familiarize yourself with the gas control valve
that your appliance uses. Refer to Figure 11
for access to the gas control valve.
To light the appliance, refer to the detailed
lighting instructions (see Pages 52 and 53).
The appliance lighting instructions may also be
found on the pull out lighting instruction labels
attached to the gas control valve.
These appliances are installed with a power
vent termination that has an exhaust blower
that expels the exhaust gases from the venting
system (see Figure 12, at right, and "Purge
Cycle," below).
PURGE CYCLE
This is a power-vented fireplace that
requires household electrical power to
operate. When the fireplace is turned
OFF, the exhaust blower will continue
to operate for up to two minutes, to
purge exhaust gases from the venting
system. This system will not operate
during a power outage.
40
WARNING
AVERTISSEMENT
11.19
(284 mm)
Inches
(millimeters)
13.50
(343 mm)
Top View
Figure 56: Power Vent Termination Specifications
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Gas Controls
The gas controls and standard controls for
appliance operation are located on the right
side of the appliance (when facing the control
side), as shown in Figure 1.
Figure 55
13.50
(343 mm)
Top View
Top View
16.17
(411 mm)
15.92
(404 mm)
Front View
Front View
Care and Operation
900358-00, 01/2018
Right Side
Modesty Panel
Access Plate
Main Gas
Shut-Off Valve
Gas Valve
Control Compartment Access
15.92
(404 mm)
11.19
(284 mm)
10.00
(254 mm)
16.17
(411 mm)
Front View