P080
Sense From Studs
P081
Electrode Polarity
P082
Voltage Sense Display
P.84
Pwr Src Select
P.95
User interface type
P099
Show Test Modes?
English
Use this option for diagnostic purposes only. When power is cycled, this option
is automatically reset to False.
"False" (default) = Voltage sensing is automatically determined by the
selected weld mode and other machine settings.
"True" = Voltage sensing is forced to "studs" of the power source.
Used in place of DIP switches for configuration of the work and electrode sense
leads
"Positive" (default) = Most GMAW welding procedures use Electrode
Positive welding.
"Negative" = Most GTAW and some inner shield procedures use Electrode
Negative welding.
Allows viewing of Voltage Sense Lead Selection to aid in troubleshooting. The
configuration is displayed as a text string on the display whenever the output is
enabled. This parameter is not saved on a power cycle, but will be reset to
False
Power Source Select – this option is only for the LADI interface. It selects the
analog power source that is connected
Determines how the user interface works:
"Feeder" (factory default) – UI works as Feeder.
"STICK/TIG" – Dedicated to work UI with a welding power source (without Wire
feeder). UI allows to set the programs for welding SMAW and GTAW process.
Note: "STICK / TIG" allows to work with an analog wire feeder also. In this
case, additional programs are avaliable for welding GMAW process in non-
synergic mode.
"Parallel" – UI works as a remote control. Parallel may be used only in parallel
with the main panel, which can be set to the "FEEDER" or "STICK / TIG".
Note: Selecting the UI type makes restart of system.
Note: Back to the factory setting forces Feeder type.
Uses for calibration and tests.
"No" (factory default) = Turned off;
"Yes" = Allows to selection test modes.
Note: After the device has been restarted the P099 is "NO".