Advertisement

Quick Links

IM3051
11/2014
REV01
WELD PAK™ 2000
OPERATOR'S MANUAL
ENGLISH
Lincoln Electric Bester Sp. z o.o.
ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland
www.lincolnelectric.eu

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric WELD PAK 2000

  • Page 1 IM3051 11/2014 REV01 WELD PAK™ 2000 OPERATOR’S MANUAL ENGLISH Lincoln Electric Bester Sp. z o.o. ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland www.lincolnelectric.eu...
  • Page 2: Declaration Of Conformity

    2006/95/CEE, 2004/108/CEE and has been designed in compliance with the following standards: EN 60974-1, EN 60974-5, EN 60974-10:2007 01.05.2014 Paweł Lipiński Operations Director Lincoln Electric Bester Sp. z o.o., ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland 07/11 English English...
  • Page 3: Table Of Contents

    12/05 THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 4: Technical Specifications

    Technical Specifications WELD PAK™ 2000 NAME INDEX WELD PAK™2000 K14134-1 INPUT Input Voltage U EMC Class Frequency 230 V ± 10% 50 / 60 Hz 1 – phase Input Amperes Input Power at Rated Cycle 1max 7,6 kVA @ 20 % Duty Cycle (40°C) 33 A 0,66 RATED OUTPUT...
  • Page 5: Electromagnetic Compatibility (Emc)

    If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances with, if necessary, assistance from Lincoln Electric Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances.
  • Page 6: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 7: Introduction

    SAFETY MARK: This equipment is suitable for supplying power for welding operations carried out in an environment with increased hazard of electric shock. CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used.
  • Page 8: Output Connections

    Input Supply Connection WARNING During SMAW process, the output terminals are still lived. WARNING Only a qualified electrician can connect the welding machine to the supply network. Installation had to be made in accordance with the appropriate National Electrical Code and local regulations. Check the input voltage, phase and frequency supplied to this machine before turning it on.
  • Page 9 6. LED Indicator Power switch: This LED lights up when the welding machine is ON and is ready to work 7. Thermal Overload Indicator: It indicates that the machine is overloaded or that the cooling is not sufficient. WARNING If the welding current exceed 200 A, output power will be turned off after 5 seconds.
  • Page 10 Table 1. Table 2. English English...
  • Page 11 Wire Spool Loading Wire spool type S300 and BS300 can be installed on the Wire Spool Type S200 Loading wire spool support without adapter. ® Wire spool type S200, B300 or Readi-Reel can be WARNING installed, but the applicable adapter must be purchased. Turn the input power OFF at the welding power source The applicable adapter can be purchased before installation or changing a wire spool.
  • Page 12 Wire Spool Type B300 Loading  Place the spool type B300 [29] on the adapter [26]. Set one of the B300 inside cage wires [30] on the slot [28] in the retaining spring tab [27] and slide the WARNING spool onto the adapter. Turn the input power OFF at the welding power source before installation or changing a wire spool.
  • Page 13  Re-install the locking nut [19]. Make sure that the Adjusting of Force of Pressure Roll locking nut is tightened. Force  Rotate the spindle and adapter so the retaining The pressure arm controls the amount of force the drive spring [32] is at the 12 o'clock position.
  • Page 14: Gas Connection

    Changing Driving Rolls WARNING Turn the input power OFF at the welding power source before installation or changing drive rolls and/or guides. ® WELD PAK™ 2000 is equipped with drive roll V0.8/V1.0 for steel wire. For others wire sizes, is available the proper drive rolls kit (see "Accessories"...
  • Page 15 Welding SMAW (MMA) Process Technical Service Center or Lincoln Electric. Repairs WELD PAK™2000 does not include the electrode and modifications performed by unauthorized service or holder with lead necessary for SMAW welding, but the personnel will cause, that the manufacturer’s warranty...
  • Page 16: Weee

    12/05 Part List reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.

This manual is also suitable for:

K14134-1

Table of Contents