To remove the selected parameter or function from the
Welding Parameters Bar [27]:
Access to the User Settings.
Use the Set Control [11] to highlight the selected
parameter or function icon which will was added to
the Welding Parameters Bar [27].
OFF
t1
t2
Figure 15
Press the Set Control [11] – The selected icon will
disappear from the display bottom.
OFF
t1
t2
Figure 16
Confirm the select – press the Right Button [12].
The User Settings Menu is closed. The Selected
parameters or function was disappeared from the
Welding Parameters Bar [27]
5.51
m
min
ArCO2
1.2
Steel
22.5
21
Figure 17
English
A/B
M
A/B
M
28.6
v
125
A
V
Preflow Time adjusts the time that shielding
t1
gas flows after the trigger is pulled and prior
to feeding.
Factory default, Preflow Time is set at 0.2 seconds.
Adjust range: from 0 seconds to 25 seconds.
OFF
0.2s
t1
t1
M
M
Postflow Time adjusts the time that
shielding gas flows after the welding output
t2
turns off.
Factory default, Postflow Time is set at 1 second.
Adjust range: from 0 seconds to 25 seconds.
OFF
t1
Burnback Time is the amount of time that
the weld output continues after the wire
stops feeding. It prevents the wire from
sticking in the puddle and prepares the end of the wire
for the next arc start.
Factory default, Burnback Time is set at 0.07
seconds.
Adjust range: from 0.01 seconds to 0.25 seconds.
0.01
t1
13
25.0
Figure 18
25.0
1.0s
t2
t2
Figure 19
0.25
0.07s
t2
M
Figure 20
English